EUVIMEDEUVIMED entdecken
Crossref

Real-time three-dimensional transthoracic echocardiography in quantification of left ventricular dyssynchrony

A. I. Mamedova, N. A. Prihod’ko, T. A. Lubimceva, A. V. Kozlenok, D. S. Lebedev

Journal of Arrhythmology · 2024

DOI: 10.35336/va-1193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Arrhythmology, 2024. Verfasst von A. I. Mamedova und 4 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To compare endocardial and epicardial left ventricular (LV) pacing using real-time electrocardiography (ECG)-synchronized three-dimensional echocardiography (3DE).

Methods

Experimental intraoperative study included 88 points obtained from 12 patients with compensated heart failure of II-IV functional class NYHA (LV ejection fraction < 35%) and cardiac resynchronization therapy indications - ECG pattern of complete left bundle branch block (LBBB) and QRS complex duration > 150 ms. During isolated LV pacing as part of cardiac resynchronization therapy implantation procedure endocardial and epicardial stimulation points matched under fluoroscopic control using quadripolar coronary sinus leads and endocardial electrodes for temporary pacing were obtained. The overall number of corresponding pacing sites included 44 endocardial and 44 epicardial stimulation positions. The mean age of patients was 68.5 [63; 73.5] years, 83% males (n=10). Before study enrollment, 12-channel ECG, echocardiography, and a six-minute walk test were performed for all participants along with cardiac magnetic resonance imaging and control coronary angiography if indicated. The prevalence of coronary heart disease was 50% (n=6) while dilated cardiomyopathy was the most common etiology of chronic heart failure in other cases. Intraoperative ECG with estimation of paced QRS complex morphology at each point was registered via LabSystem Pro Electrophysiological Recording System (Bard Electrophysiology, USA). 3DE was performed using TomTec and Philips Qlab 3DQ Advanced software (Philips Medical Systems, USA).

Results

Three-dimensional parametric imaging of LV regional segmental excursion and myocardial contractility using 3DE revealed statistically significant difference in semi-quantative parameters such as ExcAvg (p

Zitieren

APA

Mamedova, A. I., Prihod’ko, N. A., Lubimceva, T. A., Kozlenok, A. V., & Lebedev, D. S. (2024). Real-time three-dimensional transthoracic echocardiography in quantification of left ventricular dyssynchrony. Journal of Arrhythmology. https://doi.org/10.35336/va-1193

Vancouver

Mamedova AI, Prihod’ko NA, Lubimceva TA, Kozlenok AV, Lebedev DS. Real-time three-dimensional transthoracic echocardiography in quantification of left ventricular dyssynchrony. Journal of Arrhythmology. 2024. doi:10.35336/va-1193

BibTeX
@article{Mamedova2024,
  author = {Mamedova, A. I. and Prihod’ko, N. A. and Lubimceva, T. A. and Kozlenok, A. V. and Lebedev, D. S.},
  title = {Real-time three-dimensional transthoracic echocardiography in quantification of left ventricular dyssynchrony},
  journal = {Journal of Arrhythmology},
  year = {2024},
  doi = {10.35336/va-1193}
}
Kostenlos starten →