EUVIMEDEUVIMED entdecken
Crossref

Filtering blebs structure and function evaluation using optical coherence tomography

Daiva Paulaviciute-Baikstiene, Renata Vaiciuliene, Ingrida Januleviciene

Modeling and Artificial Intelligence in Ophthalmology · 2016

DOI: 10.35119/maio.v1i2.15 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Modeling and Artificial Intelligence in Ophthalmology, 2016. Verfasst von Daiva Paulaviciute-Baikstiene und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the ability of a noncontact optical coherence tomography to evaluate the morphological features of filtering blebs one year after glaucoma surgery.

Design

Prospective study.

Methods

Eighteen patients (18 eyes) with diagnosed primary open-angle glaucoma (POAG) assigned for trabeculectomy were included in the 12-month study carried out in the Eye clinic of the Lithuanian University of Health Sciences. All participants underwent trabeculectomy with 5-fluorouracil (5-FU). Bleb function was considered to be successful if the intraocular pressure (IOP) was ≤ 18 mmHg without glaucoma medications and a limited success if: 18 < IOP ≤ 21 mmHg with or without glaucoma medications at 12 months after surgery. The filtering blebs were imaged by anterior segment optical coherence tomography (AS-OCT) to evaluate the bleb wall reflectivity and measured bleb structures 12 months after trabeculectomy. Level of significance: p < 0.05 was considered significant.

Results

The mean preoperative IOP was 25.7 (6.5) mmHg and the mean number of topical glaucoma medications was 3.0 (1.2). After surgery the mean IOP was 13.8 (3.4) mmHg and glaucoma medication was 0.3 (1.0) (Wilcoxon test, p < 0.001). Analyzing bleb morphology and bleb function it was found that with uniform wall reflectivity 0 out of 3 eyes (0%) had successful bleb function and with multiform wall reflectivity 14 out of 15 eyes (93.3%) had successful bleb function 12 months after surgery (p = 0.005).We found positive correlation between IOP changes and bleb wall thickness, height of internal fluid-filled cavity (bleb height) and total bleb height (r = 0.875, 0.897, 0.939, p < 0.001).

Conclusion

AS-OCT is a useful device to assess the structure of the filtering bleb. Larger internal fluid-filled cavity, total bleb height, bigger bleb wall thickness and multiform bleb wall reflectivity were found to be good indicators of bleb function.

Zitieren

APA

Paulaviciute-Baikstiene, D., Vaiciuliene, R., & Januleviciene, I. (2016). Filtering blebs structure and function evaluation using optical coherence tomography. Modeling and Artificial Intelligence in Ophthalmology. https://doi.org/10.35119/maio.v1i2.15

Vancouver

Paulaviciute-Baikstiene D, Vaiciuliene R, Januleviciene I. Filtering blebs structure and function evaluation using optical coherence tomography. Modeling and Artificial Intelligence in Ophthalmology. 2016. doi:10.35119/maio.v1i2.15

BibTeX
@article{PaulaviciuteBaikstiene2016,
  author = {Paulaviciute-Baikstiene, Daiva and Vaiciuliene, Renata and Januleviciene, Ingrida},
  title = {Filtering blebs structure and function evaluation using optical coherence tomography},
  journal = {Modeling and Artificial Intelligence in Ophthalmology},
  year = {2016},
  doi = {10.35119/maio.v1i2.15}
}
Kostenlos starten →