Can diagnostic accuracy for early glaucoma be improved in Japanese? A trial with a potential new parameter of the RTVue OCT
Modeling and Artificial Intelligence in Ophthalmology · 2016
DOI: 10.35119/maio.v1i1.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Modeling and Artificial Intelligence in Ophthalmology, 2016. Verfasst von Yoshiyuki Kita und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Aim
To evaluate the diagnostic accuracy of the ratio of circumpapillary retinal nerve fiber layer thickness (cpRNFLT) to macular outer retinal thickness (R/O ratio) and the ratio of ganglion cell complex (GCC) thickness to outer retinal thickness (G/O ratio) measured with the RTVue-100 Fourier-domain optical coherence tomograph for detecting early glaucoma in Japanese eyes.
Methods
Forty-seven healthy control, 31 preperimetric and 70 early perimetric glaucoma eyes. We used cpRNFLT and macular retinal thickness measurements to calculate new ratio parameters, and to compare their diagnostic accuracy to those of the manufacturer-provided parameters of the RTVue-100. The ability of each parameter to diagnose glaucoma was examined by comparing the area under the receiver-operating characteristics curve (AUROC).
Results
AUROC values for the healthy vs. preperimetric glaucoma comparison were 0.842, 0.859, and 0.925 for average cpRNFLT, average R/O ratio, and average G/O ratio, respectively. For the healthy vs. early perimetric glaucoma comparison the AUROC values were 0.927, 0.933, and 0.979 for cpRNFLT, R/O ratio, and G/O ratio, respectively. Diagnostic accuracy of the R/O ratio and cpRNFLT did not differ significantly (P > 0.05). Diagnostic accuracy for the G/O ratio was significantly greater than the cpRNFLT in early glaucoma (P < 0.05).
Conclusions
Use of the G/O ratio is recommended for the detection of early glaucoma in Japanese eyes.
Zitieren
APA
Kita, Y., Hollό, G., & Kita, R. (2016). Can diagnostic accuracy for early glaucoma be improved in Japanese? A trial with a potential new parameter of the RTVue OCT. Modeling and Artificial Intelligence in Ophthalmology. https://doi.org/10.35119/maio.v1i1.1
Vancouver
Kita Y, Hollό G, Kita R. Can diagnostic accuracy for early glaucoma be improved in Japanese? A trial with a potential new parameter of the RTVue OCT. Modeling and Artificial Intelligence in Ophthalmology. 2016. doi:10.35119/maio.v1i1.1
BibTeX
@article{Kita2016,
author = {Kita, Yoshiyuki and Hollό, Gábor and Kita, Ritsuko},
title = {Can diagnostic accuracy for early glaucoma be improved in Japanese? A trial with a potential new parameter of the RTVue OCT},
journal = {Modeling and Artificial Intelligence in Ophthalmology},
year = {2016},
doi = {10.35119/maio.v1i1.1}
}
EUVIMED