EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Multimodal large language models for use in diabetic retinopathy screening

S. Saeed Mohammadi, Sahana Aggarwal, Kavina Aggarwal, Grant Wiarda, Kayla Nguyen, Emmanuel A. Sarmiento, Quan Nguyen, Manjot K. Gill

Artificial Intelligence in Vision and Ophthalmology · 11.03.2026 · 2 (1)

DOI: 10.35119/aivo.v2i1.157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Intelligence in Vision and Ophthalmology, online erschienen am 11.03.2026. Verfasst von S. Saeed Mohammadi und 7 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the performance o f ChatGPT-4o and Gemini 2.5 Pro in detecting more-than-mild diabetic retinopathy (mtmDR) from fundus photography (FP) and diabetic macular edema (DME) from optical coherence tomography (OCT) using publicly available datasets.

Methods

A custom GPT (powered by ChatGPT-4o) was created and instructed to follow the LumineticsCore™ (IDx-DR) screening criteria for mtmDR, defined as an ETDRS level ≥ 35 and/or clinically significant diabetic macular edema (CSDME). Gemini 2.5 Pro was evaluated with the same criteria. Performance on FPs was assessed using 2 publicly available datasets: MESSIDOR-2 (n = 106; 66 mtmDR, 40 no mtmDR) and EyePACS (n = 99; 56 mtmDR, 43 non-mtmDR). To assess detection of DME, a separate OCT dataset (n = 48; 24 DME, 24 normal) was used to evaluate identification of intraretinal and/or subretinal fluid. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detecting mtmDR on FP and DME on OCT were calculated for each multimodal large language model (LLM).

Results

On MESSIDOR-2 (n = 106), ChatGPT-4o achieved a sensitivity of 90.77%, specificity of 97.50%, PPV of 98.33%, and NPV of 86.67% for mtmDR detection. Gemini 2.5 Pro achieved a sensitivity of 80.30%, specificity of 97.50%, PPV of 98.15%, and NPV of 75.00%. On EyePACS (n = 99), ChatGPT-4o demonstrated a sensitivity of 94.64%, specificity of 86.05%, PPV of 89.83%, and NPV of 92.50%, while Gemini 2.5 Pro achieved a sensitivity of 89.29%, specificity of 88.37%, PPV of 90.91%, and NPV of 86.36%. For OCT-based DME detection (n = 48), ChatGPT-4o achieved a sensitivity of 95.83%, specificity of 100%, and PPV of 100%, while Gemini 2.5 Pro achieved a sensitivity of 95.83%, specificity of 95.65%, PPV of 95.83%, and NPV of 95.65%.

Conclusion

ChatGPT-4o and Gemini 2.5 Pro demonstrated high performance in detecting mtmDR and DME across multiple publicly available datasets. These findings support the potential of multimodal LLMs as cost-effective and accessible tools for diabetic retinopathy screening. Further validation in larger, more diverse real-world datasets is warranted.

Zitieren

APA

Mohammadi, S. S., Aggarwal, S., Aggarwal, K., Wiarda, G., Nguyen, K., Sarmiento, E. A., Nguyen, Q., & Gill, M. K. (2026). Multimodal large language models for use in diabetic retinopathy screening. Artificial Intelligence in Vision and Ophthalmology, 2(1). https://doi.org/10.35119/aivo.v2i1.157

Vancouver

Mohammadi SS, Aggarwal S, Aggarwal K, Wiarda G, Nguyen K, Sarmiento EA, et al. Multimodal large language models for use in diabetic retinopathy screening. Artificial Intelligence in Vision and Ophthalmology. 2026;2(1). doi:10.35119/aivo.v2i1.157

BibTeX
@article{Mohammadi2026,
  author = {Mohammadi, S. Saeed and Aggarwal, Sahana and Aggarwal, Kavina and Wiarda, Grant and Nguyen, Kayla and Sarmiento, Emmanuel A. and Nguyen, Quan and Gill, Manjot K.},
  title = {Multimodal large language models for use in diabetic retinopathy screening},
  journal = {Artificial Intelligence in Vision and Ophthalmology},
  year = {2026},
  volume = {2},
  number = {1},
  doi = {10.35119/aivo.v2i1.157}
}
Kostenlos starten →