Gas-chromatographic headspace analysis in human biomonitoring (headspace-gas chromatography)
The MAK Collection for Occupational Health and Safety · 2025 · 10 (3) · Doc057-Doc057
DOI: 10.34865/bihsgcegt10_3or ↗Kurz gefasst
Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2025. Verfasst von Michael Bader und 11 weiteren Autor:innen. Beteiligte Einrichtung: BASF SE. Corporate Health Management Carl-Bosch-Straße 38 67056 Ludwigshafen Germany. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The working group “Analyses in Biological Materials” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) describes the current status of headspace-gas chromatography with respect to its potential applications in human biomonitoring. Particular focus is given to the review and discussion of newly developed methods for headspace sample collection as well as analyte enrichment. The article gives an overview on internationally published headspace methods for the matrices urine, blood, serum and plasma, existing assessment values for headspace parameters, background exposure levels in the non-occupationally exposed general population as well as half-lives of the most prominent hazardous substances measurable by headspace methods. In addition, critical requirements for and possible pitfalls of the preanalytical phase and of the calibration of headspace analyses are also discussed. The review shows that headspace methods have been continuously improved in recent decades and thus continue to make an important contribution to human biomonitoring of occupational and environmental exposure to volatile hazardous compounds.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BASF SE. Corporate Health Management Carl-Bosch-Straße 38 67056 Ludwigshafen Germany.
- Institute of Occupational. Social and Environmental Medicine. University Medical Center of the Johannes Gutenberg-University Mainz Obere Zahlbacher Straße 67 55131 Mainz Germany.
- Friedrich-Alexander-Universität Erlangen-Nürnberg. Institute and Outpatient Clinic of Occupational, Social, and Environmental Medicine Henkestraße 9-11 91054 Erlangen Germany.
- Currenta GmbH & Co. OHG. CUR-SIT-SER-GS-BLM - Institute for Biomonitoring Chempark, Building Q18 51368 Leverkusen Germany.
- BASF Antwerpen N.V. Haven 725, Scheldelaan 600 2040 Antwerpen Belgium.
- Institute of Applied Biosciences. Department of Food Chemistry and Toxicology. Karlsruhe Institute of Technology (KIT) Adenauerring 20a, Building 50.41 76131 Karlsruhe Germany.
Zitieren
APA
Bader, M., Roßbach, B., Göen, T., Eckert, E., Schäferhenrich, A., Nübler, S., Gries, W., Leng, G., Van Pul, J., Will, W., Hartwig, A., & MAK Commission https://www.dfg.de/de/ueber-uns/gremien/senat/arbeitsstoffe/mitglieder (2025). Gas-chromatographic headspace analysis in human biomonitoring (headspace-gas chromatography). The MAK Collection for Occupational Health and Safety, 10(3), Doc057-Doc057. https://doi.org/10.34865/bihsgcegt10_3or
Vancouver
Bader M, Roßbach B, Göen T, Eckert E, Schäferhenrich A, Nübler S, et al. Gas-chromatographic headspace analysis in human biomonitoring (headspace-gas chromatography). The MAK Collection for Occupational Health and Safety. 2025;10(3):Doc057-Doc057. doi:10.34865/bihsgcegt10_3or
BibTeX
@article{Bader2025,
author = {Bader, Michael and Roßbach, Bernd and Göen, Thomas and Eckert, Elisabeth and Schäferhenrich, Anja and Nübler, Stefanie and Gries, Wolfgang and Leng, Gabriele and Van Pul, Jan and Will, Wolfgang and Hartwig, Andrea and MAK Commission https://www.dfg.de/de/ueber-uns/gremien/senat/arbeitsstoffe/mitglieder, MAK Commission https://www.dfg.de/de/ueber-uns/gremien/senat/arbeitsstoffe/mitglieder},
title = {Gas-chromatographic headspace analysis in human biomonitoring (headspace-gas chromatography)},
journal = {The MAK Collection for Occupational Health and Safety},
year = {2025},
volume = {10},
number = {3},
pages = {Doc057--Doc057},
doi = {10.34865/bihsgcegt10_3or}
}
EUVIMED