EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Precious metals – Determination of gold, silver, platinum, rhodium, and iridium in urine by ICP-SF-MS or ICP-Q-MS

Michalke, Bernhard, Blümlein, Katharina, Schirmer, Thorben, Krystek, Petra, de Kruijff, Robin, Spruit, Esther und 7 weitere

The MAK Collection for Occupational Health and Safety · 2024 · 9 (2)

DOI: 10.34865/bi7440575e9_2or ↗

Kurz gefasst

Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2024. Verfasst von Michalke und 18 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The working group “Analyses in Biological Materials” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented biomonitoring method for the determination of urinary concentrations of gold, silver, platinum, rhodium, and iridium using high-resolution inductively coupled plasma–sector-field mass spectrometry (ICP‑SF‑MS) or inductively coupled plasma‑single quadrupole mass spectrometry (ICP‑Q‑MS). The aim of this work was to establish a reliable, selective and sensitive method which is suitable for routine analysis in laboratories with high sample throughput. The method is characterised by diluting the urine samples 1 ∶ 5 (v/v) with 10% aqua regia, addition of terbium as internal standard, and determination of the concentrations of the respective precious metals by ICP‑SF‑MS or ICP‑Q‑MS. The procedure has been comprehensively validated by ICP‑SF‑MS, and the reliability data have been confirmed by replication and verification of the procedure in a second, independent laboratory using ICP‑Q‑MS. Quantitative evaluation is carried out via external calibration using precious-metal standards diluted with 10% aqua regia. The good precision and accuracy data show that the method provides reliable and accurate analytical results. The method is both selective and sensitive, and the limits of quantitation of 12.3–18.5 ng/l urine (ICP‑SF‑MS) or of 12.5 ng/l urine (ICP‑Q‑MS) are sufficient to determine occupational exposure to gold, silver, platinum, rhodium, and iridium and, in single cases, also exposure in the general population.

Schlagwörter

EdelmetalleBiomonitoringUrinICP-MSHumanbiomonitoringHBMbiologisches MonitoringArbeitnehmerArbeiterAllgemeinbevölkerung

Zitieren

APA

Michalke, Bernhard, Blümlein, Katharina, Schirmer, Thorben, Krystek, Petra, Kruijff, D., Robin, Spruit, Esther, Sarilar, Mehmet, Göen, Thomas, Hartwig, Andrea, & Commission, M. (2024). Precious metals – Determination of gold, silver, platinum, rhodium, and iridium in urine by ICP-SF-MS or ICP-Q-MS. The MAK Collection for Occupational Health and Safety, 9(2). https://doi.org/10.34865/bi7440575e9_2or

Vancouver

Michalke, Bernhard, Blümlein, Katharina, Schirmer, Thorben, et al. Precious metals – Determination of gold, silver, platinum, rhodium, and iridium in urine by ICP-SF-MS or ICP-Q-MS. The MAK Collection for Occupational Health and Safety. 2024;9(2). doi:10.34865/bi7440575e9_2or

BibTeX
@article{Michalke2024,
  author = {Michalke and Bernhard and Blümlein and Katharina and Schirmer and Thorben and Krystek and Petra and Kruijff, de and Robin and Spruit and Esther and Sarilar and Mehmet and Göen and Thomas and Hartwig and Andrea and Commission, MAK},
  title = {Precious metals – Determination of gold, silver, platinum, rhodium, and iridium in urine by ICP-SF-MS or ICP-Q-MS},
  journal = {The MAK Collection for Occupational Health and Safety},
  year = {2024},
  volume = {9},
  number = {2},
  doi = {10.34865/bi7440575e9_2or}
}
Kostenlos starten →