EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Furan – Determination of furan in exhaled air by GC-MS/MS

Ziener, Chris-Elmo, Otto, Charleen, Lorenz Contreras, Otto, Roßbach, Bernd, Lüddens-Dämgen, Kerstin, Göen, Thomas und 3 weitere

The MAK Collection for Occupational Health and Safety · 2024 · 9 (1)

DOI: 10.34865/bi11000e9_1or ↗

Kurz gefasst

Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2024. Verfasst von Ziener und 14 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The working group “Analyses in Biological Materials” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented method for the biomonitoring of furan exposure.This method focuses on the determination of furan in human end-exhaled air. Samples are collected in 20‑ml screw-top glass vials (headspace vials) into which the subjects exhale through a PTFE tube. The vials are then sealed using screw caps with PTFE-lined silicone septa. After enrichment of the furan from the gas phase by solid-phase microextraction (SPME), the extract is analysed by gas chromatography. Detection is performed using a triple-quadrupole mass spectrometer with electron-impact ionisation in Multiple Reaction Monitoring (MRM) mode. End-exhaled-air samples spiked with furan are used for external calibration.The procedure has been comprehensively validated, and the reliability data have been confirmed by replication and verification of the procedure in a second, independent laboratory. Good precision and accuracy data show that the method provides reliable and accurate analytical results. The limit of quantitation of 0.06 ng furan/l end-exhaled air is sufficient to determine occupational exposure as well as exposure to furan after smoking or shortly after coffee consumption.

Schlagwörter

Biomonitoringendexspiratorische AusatemluftSPMEHumanbiomonitoringHBMbiologisches MonitoringArbeitnehmerArbeiterAllgemeinbevölkerungArbeitsplatz

Zitieren

APA

Ziener, Chris-Elmo, Otto, Charleen, Contreras, L., Otto, Roßbach, Bernd, Lüddens-Dämgen, Kerstin, Göen, Thomas, Hartwig, Andrea, & Commission, M. (2024). Furan – Determination of furan in exhaled air by GC-MS/MS. The MAK Collection for Occupational Health and Safety, 9(1). https://doi.org/10.34865/bi11000e9_1or

Vancouver

Ziener, Chris-Elmo, Otto, Charleen, Contreras L, Otto, et al. Furan – Determination of furan in exhaled air by GC-MS/MS. The MAK Collection for Occupational Health and Safety. 2024;9(1). doi:10.34865/bi11000e9_1or

BibTeX
@article{Ziener2024,
  author = {Ziener and Chris-Elmo and Otto and Charleen and Contreras, Lorenz and Otto and Roßbach and Bernd and Lüddens-Dämgen and Kerstin and Göen and Thomas and Hartwig and Andrea and Commission, MAK},
  title = {Furan – Determination of furan in exhaled air by GC-MS/MS},
  journal = {The MAK Collection for Occupational Health and Safety},
  year = {2024},
  volume = {9},
  number = {1},
  doi = {10.34865/bi11000e9_1or}
}
Kostenlos starten →