Tartaric acid – Determination of L-(+)- and D-(–)-tartaric acid in workplace air using ion chromatography (IC)
The MAK Collection for Occupational Health and Safety · 2025 · 10 (4) · Doc068-Doc068
DOI: 10.34865/am52683e10_4or ↗Kurz gefasst
Fachartikel in der Zeitschrift The MAK Collection for Occupational Health and Safety, 2025. Verfasst von Ulrich Prott und 5 weiteren Autor:innen. Beteiligte Einrichtung: Federal Institute for Occupational Safety and Health (BAuA) Friedrich-Henkel-Weg 1-25 44149 Dortmund Germany. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The working group “Air Analyses” of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented analytical method. It is used to determine the levels of L-(+)-tartaric acid [87-69-4] and D-(–)-tartaric acid [147-71-7] (occurring as inhalable particles) individually or as a racemic mixture [133-37-9] that occur in the workplace air. The method covers concentrations in the range from one tenth up to twice the current Occupational Exposure Limit Value (OELV) of 2 mg/m3 (inhalable fraction). The method is also suitable for measuring the short-term exposure limit (STEL; excursion factor 2) for the inhalable fraction. Samples are collected by drawing a defined volume of air through a glass fibre filter, which is inserted in a GSP sampling system, using a flow regulated pump at a volumetric flow rate of 3.5 l/min. Exposure during the shift is measured with a sampling period of 2 hours and the short-term exposure with a period of 15 minutes. Tartaric acid deposited on the glass fibre filter is extracted with the IC eluent and analysed by ion chromatography using conductivity detection. The quantitative determination is based on multiple-point calibrations with external standards. A relative limit of quantification (LOQ) of 0.00043 mg/m3 is obtained for an air sample volume of 420 litres. As the LOQ for a sample volume of 52,5 litres is 0.0034 mg/m3, the STEL can also be measured. The recovery is 100–104% and the expanded uncertainty is 19–21% for a 2-hour sampling and 20–21% for a 15-minute sampling.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Federal Institute for Occupational Safety and Health (BAuA) Friedrich-Henkel-Weg 1-25 44149 Dortmund Germany.
- Federal State Saxony-Anhalt Gebrüder-Bethmann-Str. 18 06862 Dessau-Roßlau Germany.
- German Social Accident Insurance, Institution for the raw materials and chemical industry, Prevention - Department of Hazardous Substances, Biological Agents and Analytical Chemistry Kurfürsten-Anlage 62 69115 Heidelber…
- Institute of Applied Biosciences. Department of Food Chemistry and Toxicology. Karlsruhe Institute of Technology (KIT) Adenauerring 20a, Building 50.41 76131 Karlsruhe Germany.
Zitieren
APA
Prott, U., Maschmeier, C. P., Hebisch, R., Lewin-Kretzschmar, U., Hartwig, A., & MAK Commission (2025). Tartaric acid – Determination of L-(+)- and D-(–)-tartaric acid in workplace air using ion chromatography (IC). The MAK Collection for Occupational Health and Safety, 10(4), Doc068-Doc068. https://doi.org/10.34865/am52683e10_4or
Vancouver
Prott U, Maschmeier CP, Hebisch R, Lewin-Kretzschmar U, Hartwig A, MAK Commission. Tartaric acid – Determination of L-(+)- and D-(–)-tartaric acid in workplace air using ion chromatography (IC). The MAK Collection for Occupational Health and Safety. 2025;10(4):Doc068-Doc068. doi:10.34865/am52683e10_4or
BibTeX
@article{Prott2025,
author = {Prott, Ulrich and Maschmeier, Claus-Peter and Hebisch, Ralph and Lewin-Kretzschmar, Uta and Hartwig, Andrea and MAK Commission, MAK Commission},
title = {Tartaric acid – Determination of L-(+)- and D-(–)-tartaric acid in workplace air using ion chromatography (IC)},
journal = {The MAK Collection for Occupational Health and Safety},
year = {2025},
volume = {10},
number = {4},
pages = {Doc068--Doc068},
doi = {10.34865/am52683e10_4or}
}
EUVIMED