Internal Validation of a DNA Quantification Method using the Quantifiler Humand DNA Quantification Kit and the 7500 Real-Time PCR System with the Hid Real-Time PCR Analysis Software V 1.1 at the Biology Department of the Central Forensic Laboratory of the Police
Issues of Forensic Science · 2014
DOI: 10.34836/pk.2014.284.6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Issues of Forensic Science, 2014. Verfasst von Anna Spas und 1 weiteren Autor:innen.
Abstract (Originalsprache)
The aim of the present study was the internal validation of a DNA quantification method employing Ouantifiler® Humań DNA Ouantification Kit from Applied Biosystems, used for the quantification of human total DNA, coupled with the 7500 Real-Time PCR System and the HID Real-Time PCR Analysis Software v1.1, performed at the Biology Department of the Central Forensic Laboratory of the Police. The selection of parameters relevant to the laboratory’s routine casework was madę based on the ENFSI DNA Working Group recommendations included in the document Recommended Minimum Criteria for the Validation of Various Aspects of the DNA Profiling Process. The assessment regarded: sensitivity, linearity, rangę covered by the method and precision, including intralaboratory repeatability and reproducibility. Moreover, an attempt was madę to determine whether continuation of genetic analyses is rational if the 7500 Real-Time system reads are negative, i.e. no nuclear DNA is detected, while the internal positive control (IPC) results are correct. Based on conducted validation expeńments, it was found that the extent to which the validated method met the predetermined acceptance criteria is satisfactory, taking into account the specificity of the tests conducted in our laboratory. However, any negative indications of 7500 Real-Time PCR system, suggesting no presence of nuclear DNA along with correct results obtained for the IPC, should be interpreted very carefully. Apparently, it is not rational to discontinue further analyses of such samples due to the availability of very sensitive new DNA amplification kits which often allow obtaining a fuli DNA profile. To sum up, the validation of the DNA quantification method employing the Ouantifiler® Human DNA Ouantification Kit coupled with the 7500 Real-Time PCR System and the HID Real-Time PCR Analysis Software V1.1 was successful, therefore the method could be implemented and routinely used for the quantification of human total DNA in biological samples subject to forensic analyses conducted at the Biology Department of the Central Forensic Laboratory of the Police.
Zitieren
APA
Spas, A., & Zbieć-Piekarska, R. (2014). Internal Validation of a DNA Quantification Method using the Quantifiler Humand DNA Quantification Kit and the 7500 Real-Time PCR System with the Hid Real-Time PCR Analysis Software V 1.1 at the Biology Department of the Central Forensic Laboratory of the Police. Issues of Forensic Science. https://doi.org/10.34836/pk.2014.284.6
Vancouver
Spas A, Zbieć-Piekarska R. Internal Validation of a DNA Quantification Method using the Quantifiler Humand DNA Quantification Kit and the 7500 Real-Time PCR System with the Hid Real-Time PCR Analysis Software V 1.1 at the Biology Department of the Central Forensic Laboratory of the Police. Issues of Forensic Science. 2014. doi:10.34836/pk.2014.284.6
BibTeX
@article{Spas2014,
author = {Spas, Anna and Zbieć-Piekarska, Renata},
title = {Internal Validation of a DNA Quantification Method using the Quantifiler Humand DNA Quantification Kit and the 7500 Real-Time PCR System with the Hid Real-Time PCR Analysis Software V 1.1 at the Biology Department of the Central Forensic Laboratory of the Police},
journal = {Issues of Forensic Science},
year = {2014},
doi = {10.34836/pk.2014.284.6}
}
EUVIMED