EUVIMEDEUVIMED entdecken
Crossref

Facility Management and its potential new role in active infection control

Dirk Boecker, Zhang, Zhentian, Roland Breves, Herth, Dr., Clemens Bulitta

reposiTUm (TU Wien) · 01.01.2023

DOI: 10.34749/jfm.2023.4660 ↗

Kurz gefasst

Fachartikel in der Zeitschrift reposiTUm (TU Wien), erschienen am 01.01.2023. Verfasst von Dirk Boecker und 6 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Indoors, pathogen-carrying aerosol particles are recognized as important infection carriers like those in the current Corona pandemic. This infection route is often underestimated yet represents the infection route that has been least systematically addressed by counter measures to date. Current indoor safety measures (e.g.: distancing, masks, filters) provide only limited protection. Inhalation of hypochlorous acid (HOCl) containing aerosols was recently shown in several studies to be safe and effective in prevention and even in reduction of symptoms of already infected individuals (E. Rasmussen, Robins, and Williams 2021; Boecker et al. 2021b; 2021a; Wang L et al. 2007). We investigated a novel air-disinfection concept utilizing the potential of vaporized HOCl for populated facilities. Aerosolized bacterial microbes were used as surrogates for a viral contamination, particularly the enveloped coronavirus. For the facility air purification tests, we aerosolized bacterial suspensions into a controlled office space. The HOCl concentration was held at constant concentration with a software-controlled injection system (product: aerosolis® device; manufacturer: oji Europe GmbH, Nauen, Germany) and a special HOCl gas sensor unit (manufacturer: Draeger AG, Lübeck, Germany). We confirmed the disinfecting power of the used HOCl in suspensions and demonstrated the high efficacy of vaporized HOCl to deactivate airborne pathogens at safe and non-irritant levels (Test Laboratory: Microbiology Lab of Henkel, Düsseldorf, Ger-many). Incorporating this air-disinfection technology into building ventilation systems could be a valuable contribution for future infection prevention and control. It may take facility management to a new level of providing environmental safety.

Schlagwörter

facility managementhypochlorous acidaerosol disinfectionairborne pathogen transmissionindoor air qualitybuilding ventilation systemscoronavirusaerosolized bacteriainfection controloffice buildings

Zitieren

APA

Boecker, D., Zhang, Zhentian, Breves, R., Herth, Dr., & Bulitta, C. (2023). Facility Management and its potential new role in active infection control. reposiTUm (TU Wien). https://doi.org/10.34749/jfm.2023.4660

Vancouver

Boecker D, Zhang, Zhentian, Breves R, Herth, Dr., et al. Facility Management and its potential new role in active infection control. reposiTUm (TU Wien). 2023. doi:10.34749/jfm.2023.4660

BibTeX
@article{Boecker2023,
  author = {Boecker, Dirk and Zhang and Zhentian and Breves, Roland and Herth and Dr. and Bulitta, Clemens},
  title = {Facility Management and its potential new role in active infection control},
  journal = {reposiTUm (TU Wien)},
  year = {2023},
  doi = {10.34749/jfm.2023.4660}
}
Kostenlos starten →