EUVIMEDEUVIMED entdecken
Crossref

Stochastic Degradation Modeling of a Peristaltic Pump in a Biomedical Blood Autotransfusion System

Rafael Silva de Lima, Augusto Vitor Bomfim Silva Lima, Victor Vieira Rezende, Ângelo Márcio Oliveira Sant’anna

JOURNAL OF BIOENGINEERING, TECHNOLOGIES AND HEALTH · 20.05.2026 · 9 (4) · 283-288

DOI: 10.34178/jbth.v9i4.603 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JOURNAL OF BIOENGINEERING, TECHNOLOGIES AND HEALTH, online erschienen am 20.05.2026. Verfasst von Rafael Silva de Lima und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study compares two stochastic models, Brownian Motion with Drift and the pure Wiener Process, applied to the degradation of a peristaltic pump used in a biomedical device. Failure was defined as the reduction of flow rate below a critical threshold required for safe operation. Simulations showed that the Wiener Process consistently produced higher time-to-failure (TTF) values across all scenarios, with larger differences under low and moderate variability (σ = 0.05 and σ = 0.3) and smaller differences under high variability (σ = 0.8). The observed effect results from the deterministic component in Brownian Motion with Drift, which accelerates average degradation, while the Wiener Process is driven solely by random fluctuations, allowing greater variability in failure time. Findings indicate that, in biomedical applications, selecting an appropriate degradation model is crucial for accurate lifetime predictions and predictive maintenance planning, particularly in low-variability environments. Future work should integrate stochastic degradation models with statistical monitoring techniques to improve early fault-detection accuracy and enhance the robustness of lifetime estimation under real operating conditions.

Zitieren

APA

Lima, R. S. D., Lima, A. V. B. S., Rezende, V. V., & Sant’anna, Â. M. O. (2026). Stochastic Degradation Modeling of a Peristaltic Pump in a Biomedical Blood Autotransfusion System. JOURNAL OF BIOENGINEERING, TECHNOLOGIES AND HEALTH, 9(4), 283-288. https://doi.org/10.34178/jbth.v9i4.603

Vancouver

Lima RSD, Lima AVBS, Rezende VV, Sant’anna ÂMO. Stochastic Degradation Modeling of a Peristaltic Pump in a Biomedical Blood Autotransfusion System. JOURNAL OF BIOENGINEERING, TECHNOLOGIES AND HEALTH. 2026;9(4):283-288. doi:10.34178/jbth.v9i4.603

BibTeX
@article{Lima2026,
  author = {Lima, Rafael Silva de and Lima, Augusto Vitor Bomfim Silva and Rezende, Victor Vieira and Sant’anna, Ângelo Márcio Oliveira},
  title = {Stochastic Degradation Modeling of a Peristaltic Pump in a Biomedical Blood Autotransfusion System},
  journal = {JOURNAL OF BIOENGINEERING, TECHNOLOGIES AND HEALTH},
  year = {2026},
  volume = {9},
  number = {4},
  pages = {283--288},
  doi = {10.34178/jbth.v9i4.603}
}
Kostenlos starten →