EUVIMEDEUVIMED entdecken
Crossref

CBCT Evaluation of Rotary vs. Reciprocating NiTi Systems for Gutta-Percha Removal: An Ex Vivo Study

Melika Razaghi, Ali Kazemi, Parisa Bagheri, Hadi Assadian

Journal of Iranian Dental Association · 01.01.2026 · 38 (1-2) · 23-31

DOI: 10.34172/jida.2287 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Iranian Dental Association, online erschienen am 23.05.2026. Verfasst von Melika Razaghi und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This ex vivo study compared the efficacy of Mtwo rotary and Reciproc reciprocating NiTi systems in removing gutta-percha from the mesiobuccal canals of human maxillary and mandibular first molars using cone-beam computed tomography (CBCT). Materials and Methods: Ninety mesial roots from extracted maxillary and mandibular firs molars were included. Each root presented a closed apex and a curvature angle of ˂ 20°. The crowns were sectioned at the CEJ, and the canal lenghths were standardized to 12 mm. he canals were prepared and obturated with gutta-percha and AH26 sealer using lateral condensation technique. Samples were randomly assigned to two retreatment groups: Mtwo (multi-file rotary system) and Reciproc (single-file reciprocating system). Gutta-percha removal followed standardized protocols, with CBCT imaging performed pre- and post-retreatment. Residual filling materials were evaluated at 2.5, 5, and 7 mm from the apex. Statistical analysis was conducted using chi-square and Wilcoxon tests.

Results

Complete removal of obturation materials was not achieved by either system. Residual material in the Mtwo group was 16.90%, 11.86%, and 7.45% at 2.5, 5, and 7 mm, respectively; in the Reciproc group, it was 24.61%, 19.83%, and 16.24%. No significant differences were observed at 2.5 and 5 mm (P ˃ 0.05), while Mtwo showed superior efficacy at 7 mm (P=0.042).

Conclusion

Complete removal of gutta-percha was not achieved in any of the groups. Mtwo was more efficient in gutta- percha removal at 7-mm section. Moreover,the single‑file design of the Reciproc system was associated with procedural simplification

Zitieren

APA

Razaghi, M., Kazemi, A., Bagheri, P., & Assadian, H. (2026). CBCT Evaluation of Rotary vs. Reciprocating NiTi Systems for Gutta-Percha Removal: An Ex Vivo Study. Journal of Iranian Dental Association, 38(1-2), 23-31. https://doi.org/10.34172/jida.2287

Vancouver

Razaghi M, Kazemi A, Bagheri P, Assadian H. CBCT Evaluation of Rotary vs. Reciprocating NiTi Systems for Gutta-Percha Removal: An Ex Vivo Study. Journal of Iranian Dental Association. 2026;38(1-2):23-31. doi:10.34172/jida.2287

BibTeX
@article{Razaghi2026,
  author = {Razaghi, Melika and Kazemi, Ali and Bagheri, Parisa and Assadian, Hadi},
  title = {CBCT Evaluation of Rotary vs. Reciprocating NiTi Systems for Gutta-Percha Removal: An Ex Vivo Study},
  journal = {Journal of Iranian Dental Association},
  year = {2026},
  volume = {38},
  number = {1-2},
  pages = {23--31},
  doi = {10.34172/jida.2287}
}