Iatrogenic Fracture of a Peripheral Intravenous Cannula: A Case Report
Journal of Caring Sciences · 24.02.2026 · 15 (1) · 61-64
DOI: 10.34172/jcs.026.33750 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Caring Sciences, online erschienen am 24.02.2026. Verfasst von Anandaperumal Pachiyappan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Liver Transplant ICU, JIPMER,Puducherry. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Peripheral intravenous cannulation is a routine invasive procedure widely used in healthcare settings. While it is typically associated with minimal risk, uncommon complications such as cannula fracture and intravascular migration may occur. They can result in significant morbidity if diagnosis and intervention are delayed. Case Report: We describe an adult patient who developed an iatrogenic fracture of a peripheral intravenous cannula, with proximal displacement of the fractured segment into the brachial vein. Ultrasonography was employed to identify and localize the intravascular foreign body. A catheter fragment measuring approximately 2.5 cm was surgically removed via venotomy performed about 5 cm proximal to the initial cannulation site. The patient recovered uneventfully, with no postoperative complications.
Conclusion
Although rare, fracture and migration of peripheral intravenous cannulas constitute a serious iatrogenic event. Prompt imaging, particularly with ultrasound, is essential for accurate detection and localization. This case emphasizes the need for meticulous cannula insertion and removal practices, along with heightened clinical vigilance, to improve patient safety and prevent avoidable complications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Liver Transplant ICU, JIPMER,Puducherry.
- Department of Surgical Gastroenterology, JIPMER.
- College of Nursing, JIPMER, Puducherry-06, India.
ORCID-Profile: Anandaperumal Pachiyappan, Amirthavalli Athimulam, Kalayarasan Raja, Lakshmi Ramamoorthy
Zitieren
APA
Pachiyappan, A., Athimulam, A., Raja, K., & Ramamoorthy, L. (2026). Iatrogenic Fracture of a Peripheral Intravenous Cannula: A Case Report. Journal of Caring Sciences, 15(1), 61-64. https://doi.org/10.34172/jcs.026.33750
Vancouver
Pachiyappan A, Athimulam A, Raja K, Ramamoorthy L. Iatrogenic Fracture of a Peripheral Intravenous Cannula: A Case Report. Journal of Caring Sciences. 2026;15(1):61-64. doi:10.34172/jcs.026.33750
BibTeX
@article{Pachiyappan2026,
author = {Pachiyappan, Anandaperumal and Athimulam, Amirthavalli and Raja, Kalayarasan and Ramamoorthy, Lakshmi},
title = {Iatrogenic Fracture of a Peripheral Intravenous Cannula: A Case Report},
journal = {Journal of Caring Sciences},
year = {2026},
volume = {15},
number = {1},
pages = {61--64},
doi = {10.34172/jcs.026.33750}
}
EUVIMED