EUVIMEDEUVIMED entdecken
Crossref

Micellar Enhanced Ultrafiltration (MEUF) Using Cetylpyridinium Chloride (CPC) and Hexadecyltrimethylammonium Bromide (HDTAB) Surfactants for Fluoride Rejection: Modeling and Process Optimization

Sodabeh Heidarnejad, Ali Jafari, Seyyed Alireza Mousavi, Mohammad Javad Shokoohizadeh

Journal of Advances in Environmental Health Research · 29.03.2026 · 14 (1) · 64-71

DOI: 10.34172/jaehr.1444 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Advances in Environmental Health Research, online erschienen am 29.03.2026. Verfasst von Sodabeh Heidarnejad und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The current study aimed to optimize micellar-enhanced ultrafiltration (MEUF), a low-pressure membrane method, for removing fluoride from water, a contaminant linked to serious health risks such as fluorosis-through two cationic surfactants.

Methods

In this study, a dead-end ultrafiltration system was employed to remove fluoride using cetylpyridinium chloride (CPC) and hexadecyltrimethylammonium bromide (HDTAB). Important operational parameters such as pH (4-10), initial fluoride concentration (4-10 mg/L), and surfactant concentration (0.5-1.5 mM) were modeled and optimized via Response Surface Methodology (RSM) based on a Box-Behnken design.

Results

Analysis of variance (ANOVA) confirmed the high significance of the developed quadratic models, with regression coefficients (R2) of 0.99 and 0.97 for CPC and HDTAB, respectively. The optimal removal efficiencies were 94.5% for CPC (at pH 8, 1.2 mM CPC, 8 mg/L F-) and 89.6% for HDTAB (at pH 7, 1.4 mM HDTAB, 10 mg/L F-). Under the optimum conditions, flux values of 268.1 L/m2.h and 276.5 L/m2.h were also obtained for CPC and HDTAB, respectively.

Conclusion

It was found that MEUF is an effective technique for fluoride rejection. And the RSM successfully modeled and optimized the process, with CPC demonstrating superior performance and model predictability compared to HDTAB. These observations suggest that the proposed system can be reliably applied to larger-scale fluoride removal from aqueous solutions.

Zitieren

APA

Heidarnejad, S., Jafari, A., Mousavi, S. A., & Shokoohizadeh, M. J. (2026). Micellar Enhanced Ultrafiltration (MEUF) Using Cetylpyridinium Chloride (CPC) and Hexadecyltrimethylammonium Bromide (HDTAB) Surfactants for Fluoride Rejection: Modeling and Process Optimization. Journal of Advances in Environmental Health Research, 14(1), 64-71. https://doi.org/10.34172/jaehr.1444

Vancouver

Heidarnejad S, Jafari A, Mousavi SA, Shokoohizadeh MJ. Micellar Enhanced Ultrafiltration (MEUF) Using Cetylpyridinium Chloride (CPC) and Hexadecyltrimethylammonium Bromide (HDTAB) Surfactants for Fluoride Rejection: Modeling and Process Optimization. Journal of Advances in Environmental Health Research. 2026;14(1):64-71. doi:10.34172/jaehr.1444

BibTeX
@article{Heidarnejad2026,
  author = {Heidarnejad, Sodabeh and Jafari, Ali and Mousavi, Seyyed Alireza and Shokoohizadeh, Mohammad Javad},
  title = {Micellar Enhanced Ultrafiltration (MEUF) Using Cetylpyridinium Chloride (CPC) and Hexadecyltrimethylammonium Bromide (HDTAB) Surfactants for Fluoride Rejection: Modeling and Process Optimization},
  journal = {Journal of Advances in Environmental Health Research},
  year = {2026},
  volume = {14},
  number = {1},
  pages = {64--71},
  doi = {10.34172/jaehr.1444}
}
Kostenlos starten →