EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Detection of SARS-CoV-2 in Iraqi Patient Samples

Maytham Khazaal Kadhim, Luay Abbas Faisal Al- Sahlanee, Muayad Khayoon Ajahli, Ali Raheem Abbood Al Musawi, Rana Riyadh Al-Ani

International Journal of Medical Parasitology and Epidemiology Sciences · 29.06.2026 · 7 (2) · 119-126

DOI: 10.34172/ijmpes.6272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Medical Parasitology and Epidemiology Sciences, online erschienen am 29.06.2026. Verfasst von Maytham Khazaal Kadhim und 4 weiteren Autor:innen. Die Arbeit nennt 63 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The COVID-19 pandemic has accelerated the need for rapid, accurate, and cost-effective diagnostic methods. Although RT-qPCR is the first-line solution, in the context of limited resources such as Iraq alternatives like RT-LAMP should be evaluated. Aim of this study is evaluation the diagnostic efficacy of RT-LAMP for the screening for SARS-CoV-2 in Iraqi patient samples against RT-qPCR.

Methods

This cross-sectional study was performed on 350 nasopharyngeal swab samples from patients aged between 15-60 years in all Iraqi governorates sampled from January-March 2023. The RT-LAMP and RT-qPCR assays were conducted in parallel on all samples. Diagnostic performance parameters such as sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and overall accuracy were determined.

Results

RT-LAMP performed comparably to RT-qPCR and achieved sensitivity of 96.2% (95% CI 92.8–98.3) and specificity of 98.1% (95% CI 95.2–99.5). The positive predictive value was 97.8% (95% CI: 94.9–99.3) and negative predictive value was 96.7% (95% CI: 93.5–98.6). Detection limit for RT-LAMP was 10 copies/μL, and total assay time from sample to result was 45 min.

Conclusion

RT-LAMP is a confirmed, rapid and inexpensive alternative for detecting SARS-CoV-2 in Iraq, and may be suitable for use at resource constrained settings and point-of-care testing.

Zitieren

APA

Kadhim, M. K., Sahlanee, L. A. F. A., Ajahli, M. K., Musawi, A. R. A. A., & Al-Ani, R. R. (2026). Evaluation of Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Detection of SARS-CoV-2 in Iraqi Patient Samples. International Journal of Medical Parasitology and Epidemiology Sciences, 7(2), 119-126. https://doi.org/10.34172/ijmpes.6272

Vancouver

Kadhim MK, Sahlanee LAFA, Ajahli MK, Musawi ARAA, Al-Ani RR. Evaluation of Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Detection of SARS-CoV-2 in Iraqi Patient Samples. International Journal of Medical Parasitology and Epidemiology Sciences. 2026;7(2):119-126. doi:10.34172/ijmpes.6272

BibTeX
@article{Kadhim2026,
  author = {Kadhim, Maytham Khazaal and Sahlanee, Luay Abbas Faisal Al- and Ajahli, Muayad Khayoon and Musawi, Ali Raheem Abbood Al and Al-Ani, Rana Riyadh},
  title = {Evaluation of Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Detection of SARS-CoV-2 in Iraqi Patient Samples},
  journal = {International Journal of Medical Parasitology and Epidemiology Sciences},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {119--126},
  doi = {10.34172/ijmpes.6272}
}
Kostenlos starten →