Health Risk Assessment, Determining, and Identifying the Fungal Aerosol in the Operating Room Air of Hospitals in Southwestern Iran
Environmental Health Engineering and Management · 05.02.2026 · 13 · 1314
DOI: 10.34172/ehem.1314 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Health Engineering and Management, online erschienen am 05.02.2026. Verfasst von Maryam Hormati und 6 weiteren Autor:innen. Die Arbeit nennt 65 Literaturangaben.
Abstract (Originalsprache)
Background
Nosocomial infection (NIs) is caused by pathogenic reactions related to the infectious agent itself or its toxins in the hospital. Air pollution can include fungal and bacterial pollutionwhich are among the main factors for the prevalence of NIs. This study aimed to determine the quantitative and qualitative amount of fungal aerosol in the indoor air of hospital operating rooms.
Methods
In this descriptive-analytical study, the concentration of fungal aerosol in operating rooms was studied. Sampling of fungal aerosol was done by Quick Take 30 with a flow rate of 28.3 L/min and a duration of 5 minutes on Sabro dextrose agar culture medium containing chloramphenicol antibiotic.
Results
Based on the findings of the study, it was found that the average total fungal aerosol density in public and private sector hospitals was 9.8 and 4.1 CFU/m3 , respectively. The highest prevalence of isolated fungi during the sampling period in the public hospital was Trichophyton with an average frequency of 52.5% and in the private sector hospital was Aspergillus with an average frequency of 41.5%. The results showed that for fungal aerosol, the health risk assessment indicated that occupants in the indoor air of hospital operating rooms had an acceptable exposure risk (hazard index
Zitieren
APA
Hormati, M., Haghighifard, N. J., Montazeri, E. A., Ghanbari, S., Dehaghi, B. F., Ghomeishi, A., & Mohammadi, M. J. (2026). Health Risk Assessment, Determining, and Identifying the Fungal Aerosol in the Operating Room Air of Hospitals in Southwestern Iran. Environmental Health Engineering and Management, 13, 1314. https://doi.org/10.34172/ehem.1314
Vancouver
Hormati M, Haghighifard NJ, Montazeri EA, Ghanbari S, Dehaghi BF, Ghomeishi A, et al. Health Risk Assessment, Determining, and Identifying the Fungal Aerosol in the Operating Room Air of Hospitals in Southwestern Iran. Environmental Health Engineering and Management. 2026;13:1314. doi:10.34172/ehem.1314
BibTeX
@article{Hormati2026,
author = {Hormati, Maryam and Haghighifard, Nematollah Jaafarzadeh and Montazeri, Effat Abbasi and Ghanbari, Saeed and Dehaghi, Behzad Fouladi and Ghomeishi, Ali and Mohammadi, Mohammad Javad},
title = {Health Risk Assessment, Determining, and Identifying the Fungal Aerosol in the Operating Room Air of Hospitals in Southwestern Iran},
journal = {Environmental Health Engineering and Management},
year = {2026},
volume = {13},
pages = {1314},
doi = {10.34172/ehem.1314}
}
EUVIMED