EUVIMEDEUVIMED entdecken
Crossref

Design and evaluation of a multifunctional electrospun scaffold loaded with amniotic membrane and allantoin for dermal tissue engineering

Nahid Heidari Hafshejani, Azam Rahimpour, Hojjat Allah Abbaszadeh, Hojatollah Montazeri, Sepideh Ghani, Simzar Hosseinzadeh, Bahram Kazemi

BioImpacts · 11.11.2026 · 16 · 33538

DOI: 10.34172/bi.33538 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BioImpacts, online erschienen am 11.11.2026. Verfasst von Nahid Heidari Hafshejani und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Chronic wounds remain difficult to treat because healing is impaired, inflammation persists, and infection risk is high. Whether a spatially organized three-layer electrospun scaffold containing amniotic membrane powder and allantoin can combine mechanical support with sustained bioactive delivery during full-thickness dermal regeneration remains unclear.

Methods

The scaffold was electrospun in 3 layers: polyurethane, polyethylene oxide containing amniotic membrane powder and allantoin, and a gelatin/carbomer blend. Physicochemical properties and fibroblast responses were assessed, followed by wound healing in a rat full-thickness excisional model (n = 12 per group; n = 3 per time point) over 21 days.

Results

All layers displayed uniform nanofibers. The 3L/Amnion/Allantoin scaffold reached an ultimate tensile strength of 38.19 MPa. Superhydrophilic behavior, with a contact angle of 0°, was observed for 3L/Allantoin. The 3L/Amnion/Allantoin scaffold increased fibroblast viability (P < 0.0001 versus controls at day 14) and upregulated VEGF (2-fold) and DDR2 (1.7-fold) expression. On day 7, wound closure reached 50.0 ± 1.0% in the 3L/Fibroblast/Amnion/Allantoin group versus 15.0 ± 1.0% in the untreated control (P < 0.0001). By day 14, this group reached 90.0 ± 1.0% closure versus 50.0 ± 1.0% in controls (P < 0.0001), accompanied by accelerated re-epithelialization and organized collagen deposition. By day 21, wound closure reached ≥ 99% in all groups, with no significant intergroup differences.

Conclusion

The three-layer scaffold combined structural reinforcement with local bioactive delivery and accelerated wound closure through day 14, supporting further evaluation in dermal tissue engineering.

Zitieren

APA

Hafshejani, N. H., Rahimpour, A., Abbaszadeh, H. A., Montazeri, H., Ghani, S., Hosseinzadeh, S., & Kazemi, B. (2026). Design and evaluation of a multifunctional electrospun scaffold loaded with amniotic membrane and allantoin for dermal tissue engineering. BioImpacts, 16, 33538. https://doi.org/10.34172/bi.33538

Vancouver

Hafshejani NH, Rahimpour A, Abbaszadeh HA, Montazeri H, Ghani S, Hosseinzadeh S, et al. Design and evaluation of a multifunctional electrospun scaffold loaded with amniotic membrane and allantoin for dermal tissue engineering. BioImpacts. 2026;16:33538. doi:10.34172/bi.33538

BibTeX
@article{Hafshejani2026,
  author = {Hafshejani, Nahid Heidari and Rahimpour, Azam and Abbaszadeh, Hojjat Allah and Montazeri, Hojatollah and Ghani, Sepideh and Hosseinzadeh, Simzar and Kazemi, Bahram},
  title = {Design and evaluation of a multifunctional electrospun scaffold loaded with amniotic membrane and allantoin for dermal tissue engineering},
  journal = {BioImpacts},
  year = {2026},
  volume = {16},
  pages = {33538},
  doi = {10.34172/bi.33538}
}
Kostenlos starten →