EUVIMEDEUVIMED entdecken
Open Access

Exploration of Automated Measurement for Ossicular Chains Based on 3-Dimensional Geometric Information

Mengshi Zhang, Yufan Zhang, Sihui Guo, Xiaoguang Li, Li Zhuo, Yuxue Ren, Wei Chen, Yili Feng, Ruowei Tang, Han Lv, Pengfei Zhao, Zhenchang Wang und 1 weitere

Cyborg and Bionic Systems · 2025-01 · 6

DOI: 10.34133/cbsystems.0305 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cyborg and Bionic Systems, online erschienen am 02.07.2025. Verfasst von Mengshi Zhang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, Beijing Science and Technology Planning Project, Beijing Scholar 2015.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Abnormalities in the ossicular chain, a key middle-ear component that is crucial for sound transmission, can lead to conductive hearing loss; reconstruction offers an effective treatment. Accurate preoperative ossicular-chain measurements are essential for creating prostheses; however, current methods rely on cadaver studies or manual measurements from 2-dimensional images, which are time-intensive and laborious and depend heavily on radiologist expertise. To improve efficiency, we aimed to develop a systematic approach for automated ossicular-chain segmentation and measurement using ultra-high-resolution computed tomography (U-HRCT). One hundred forty patients (226 ears) with normal ear anatomy underwent U-HRCT. Twelve parameters were defined to measure ossicular-chain components. Automated measurements based on automated segmentation of 226 ear images were verified through manual measurements. We analyzed variations by ear side, sex, and age group. Stapes analysis was limited by segmentation accuracy. Complete segmentation of the malleus, incus, and stapes was achieved in 47 ears. Automated measurements of 8 parameters showed no significant differences compared to manual measurements in 47 cases. Significant sex-based differences emerged in all parameters except stapes footplate length, incudostapedial joint angle, and stapes volume ( P = 0.205, P = 0.560, and P = 0.170, respectively). Notable side-specific differences were observed in female incus height and male malleus volume ( P = 0.017 and P = 0.037, respectively). No statistically significant differences were found in other parameters across different age groups, except for malleus and incus volumes ( P = 0.015 and P = 0.031). The proposed algorithm effectively automated ossicular-chain segmentation and measurement, establishing a normative range for ossicular parameters and providing a valuable reference for detecting abnormalities.

Autor:innen und Institutionen

  • Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.
  • Beijing Key Laboratory of Computational Intelligence and Intelligent System, Beijing University of Technology, Beijing 100124, China.
  • Academy for Multidisciplinary Studies, Capital Normal University, Beijing 100048, China.
  • Department of Medical Engineering, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China.
  • Department of Automation, Tsinghua University, Beijing 100084, China.

ORCID-Profile: Hongxia Yin

Förderung

  • National Natural Science Foundation of China
  • Beijing Science and Technology Planning Project
  • Beijing Scholar 2015
  • Capital’s Funds for Health Improvement and Research

Zitieren

APA

Zhang, M., Zhang, Y., Guo, S., Li, X., Zhuo, L., Ren, Y., Chen, W., Feng, Y., Tang, R., Lv, H., Zhao, P., Wang, Z., & Yin, H. (2025). Exploration of Automated Measurement for Ossicular Chains Based on 3-Dimensional Geometric Information. Cyborg and Bionic Systems, 6. https://doi.org/10.34133/cbsystems.0305

Vancouver

Zhang M, Zhang Y, Guo S, Li X, Zhuo L, Ren Y, et al. Exploration of Automated Measurement for Ossicular Chains Based on 3-Dimensional Geometric Information. Cyborg and Bionic Systems. 2025;6. doi:10.34133/cbsystems.0305

BibTeX
@article{Zhang2025,
  author = {Zhang, Mengshi and Zhang, Yufan and Guo, Sihui and Li, Xiaoguang and Zhuo, Li and Ren, Yuxue and Chen, Wei and Feng, Yili and Tang, Ruowei and Lv, Han and Zhao, Pengfei and Wang, Zhenchang and Yin, Hongxia},
  title = {Exploration of Automated Measurement for Ossicular Chains Based on 3-Dimensional Geometric Information},
  journal = {Cyborg and Bionic Systems},
  year = {2025},
  volume = {6},
  doi = {10.34133/cbsystems.0305}
}
Kostenlos starten →