Robotic Ultrasound Scanning End-Effector with Adjustable Constant Contact Force

Zehao Wu, Xianli Wang, Yuning Cao, Weijian Zhang, Qingsong Xu iD

Cyborg and Bionic Systems · 2025-01 · 6

DOI: 10.34133/cbsystems.0251 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cyborg and Bionic Systems, online erschienen am 02.05.2025. Verfasst von Zehao Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electromechanical Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau, China. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, Fundo para o Desenvolvimento das Ciências e da Tecnologia, Research Services and Knowledge Transfer Office, University of Macau.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In modern medical treatment, ultrasound scanning provides a radiation-free medical imaging method for the diagnosis of soft tissues via skin contact. However, the exerted contact force heavily relies on the skill and experience of the operator, which poses great inspection instability. This article reports on a robotic ultrasound scanning system with a constant-force end-effector. Its uniqueness is the introduction of a hybrid active–passive force control approach to maintaining a constant contact force between the ultrasound probe and the continually changing surface. In particular, the passive constant-force mechanism provides strong buffering to the force variation. The active force control system improves flexibility and provides long-stroke positioning. Experimental tests on both silicone models and human volunteers demonstrate the capability of the proposed robotic ultrasound scanning system for obtaining qualified ultrasound images with high repeatability. Moreover, the ease of operation of the robotic US scanning system is verified. This work provides a promising method to assist doctors in conducting better and cushier ultrasound scanning imaging.

Autor:innen und Institutionen

  • Department of Electromechanical Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau, China.

ORCID-Profile: Qingsong Xu

Förderung

  • National Natural Science Foundation of China
  • Fundo para o Desenvolvimento das Ciências e da Tecnologia
  • Research Services and Knowledge Transfer Office, University of Macau

Zitieren

APA

Wu, Z., Wang, X., Cao, Y., Zhang, W., & Xu, Q. (2025). Robotic Ultrasound Scanning End-Effector with Adjustable Constant Contact Force. Cyborg and Bionic Systems, 6. https://doi.org/10.34133/cbsystems.0251

Vancouver

Wu Z, Wang X, Cao Y, Zhang W, Xu Q. Robotic Ultrasound Scanning End-Effector with Adjustable Constant Contact Force. Cyborg and Bionic Systems. 2025;6. doi:10.34133/cbsystems.0251

BibTeX
@article{Wu2025,
  author = {Wu, Zehao and Wang, Xianli and Cao, Yuning and Zhang, Weijian and Xu, Qingsong},
  title = {Robotic Ultrasound Scanning End-Effector with Adjustable Constant Contact Force},
  journal = {Cyborg and Bionic Systems},
  year = {2025},
  volume = {6},
  doi = {10.34133/cbsystems.0251}
}
Kostenlos starten →