A Novel Electromagnetic Driving System for 5-DOF Manipulation in Intraocular Microsurgery
Cyborg and Bionic Systems · 2024-01 · 5
DOI: 10.34133/cbsystems.0083 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cyborg and Bionic Systems, online erschienen am 23.03.2024. Verfasst von Yangyu Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin 30007…. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
This work presents a novel electromagnetic driving system that consists of eight optimized electromagnets arranged in an optimal configuration and employs a control framework based on an active disturbance rejection controller (ADRC) and virtual boundary. The optimal system configuration enhances the system’s compatibility with other ophthalmic surgical instruments, while also improving its capacity to generate magnetic force in the vertical direction. Besides, the optimal electromagnet parameters provide a superior comprehensive performance on magnetic field generation capacity and thermal power. Hence, the presented design achieves a stronger capacity for sustained work. Furthermore, the ADRC controller effectively monitors and further compensates the total disturbance as well as gravity to enhance the system’s robustness. Meanwhile, the implementation of virtual boundaries substantially enhances interactive security via collision avoidance. The magnetic and thermal performance tests have been performed on the electromagnet to verify the design optimization. The proposed electromagnet can generate a superior magnetic field of 2.071 mT at a distance of 65 mm with an applied current of 1 A. Moreover, it demonstrates minimal temperature elevation from room temperature (25 °C) to 46 °C through natural heat dissipation in 3 h, thereby effectively supporting prolonged magnetic manipulation of intraocular microsurgery. Furthermore, trajectory tracking experiments with disturbances have been performed in a liquid environment similar to the practical ophthalmic surgery scenarios, to verify the robustness and security of the presented control framework. The maximum root mean square (RMS) error of performance tests in different operation modes remains 35.8 μm, providing stable support for intraocular microsurgery.
Autor:innen und Institutionen
- Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin 300072, China.
- Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities, Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen 518055, Chi…
Zitieren
APA
Liu, Y., Song, D., Zhang, G., Bu, Q., Dong, Y., Hu, C., & Shi, C. (2024). A Novel Electromagnetic Driving System for 5-DOF Manipulation in Intraocular Microsurgery. Cyborg and Bionic Systems, 5. https://doi.org/10.34133/cbsystems.0083
Vancouver
Liu Y, Song D, Zhang G, Bu Q, Dong Y, Hu C, et al. A Novel Electromagnetic Driving System for 5-DOF Manipulation in Intraocular Microsurgery. Cyborg and Bionic Systems. 2024;5. doi:10.34133/cbsystems.0083
BibTeX
@article{Liu2024,
author = {Liu, Yangyu and Song, Dezhi and Zhang, Guanghao and Bu, Qingyu and Dong, Yuanqing and Hu, Chengzhi and Shi, Chaoyang},
title = {A Novel Electromagnetic Driving System for 5-DOF Manipulation in Intraocular Microsurgery},
journal = {Cyborg and Bionic Systems},
year = {2024},
volume = {5},
doi = {10.34133/cbsystems.0083}
}
EUVIMED