EUVIMEDEUVIMED entdecken
Open Access

Quantifying Sharpness and Nonlinearity in Neonatal Seizure Dynamics

Chien-Hung Yeh, Chuting Zhang, Wenbin Shi, Boyi Zhang, Jianping An

Cyborg and Bionic Systems · 2024-01 · 5

DOI: 10.34133/cbsystems.0076 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cyborg and Bionic Systems, online erschienen am 25.01.2024. Verfasst von Chien-Hung Yeh und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Information and Electronics, Beijing Institute of Technology, Beijing, China. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The integration of multiple electrophysiological biomarkers is crucial for monitoring neonatal seizure dynamics. The present study aimed to characterize the temporal dynamics of neonatal seizures by analyzing intrinsic waveforms of epileptic electroencephalogram (EEG) signals. We proposed a complementary set of methods considering envelope power, focal sharpness changes, and nonlinear patterns of EEG signals of 79 neonates with seizures. Features derived from EEG signals were used as input to the machine learning classifier. All three characteristics were significantly elevated during seizure events, as agreed upon by all viewers ( P < 0.0001). Envelope power was elevated in the entire seizure period, and the degree of nonlinearity rose at the termination of a seizure event. Epileptic sharpness effectively characterizes an entire seizure event, complementing the role of envelope power in identifying its onset. However, the degree of nonlinearity showed superior discriminability for the termination of a seizure event. The proposed computational methods for intrinsic sharp or nonlinear EEG patterns evolving during neonatal seizure could share some features with envelope power. Current findings may be helpful in developing strategies to improve neonatal seizure monitoring.

Autor:innen und Institutionen

  • School of Information and Electronics, Beijing Institute of Technology, Beijing, China.
  • Key Laboratory of Brain Health Intelligent Evaluation and Intervention (Beijing Institute of Technology), Ministry of Education, Beijing, China.
  • School of Engineering, University of Edinburgh, Edinburgh, UK.
  • School of Cyberspace Science and Technology, Beijing Institute of Technology, Beijing, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yeh, C. H., Zhang, C., Shi, W., Zhang, B., & An, J. (2024). Quantifying Sharpness and Nonlinearity in Neonatal Seizure Dynamics. Cyborg and Bionic Systems, 5. https://doi.org/10.34133/cbsystems.0076

Vancouver

Yeh CH, Zhang C, Shi W, Zhang B, An J. Quantifying Sharpness and Nonlinearity in Neonatal Seizure Dynamics. Cyborg and Bionic Systems. 2024;5. doi:10.34133/cbsystems.0076

BibTeX
@article{Yeh2024,
  author = {Yeh, Chien-Hung and Zhang, Chuting and Shi, Wenbin and Zhang, Boyi and An, Jianping},
  title = {Quantifying Sharpness and Nonlinearity in Neonatal Seizure Dynamics},
  journal = {Cyborg and Bionic Systems},
  year = {2024},
  volume = {5},
  doi = {10.34133/cbsystems.0076}
}
Kostenlos starten →