Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis

Kazuhiko Shibata iD, Hiroyoshi Fukui, Tamio Iwamoto, Sanae Saka, Yuki Kawai, Takeshi Aoki, Ryo Shibata, Kanenori Maeda, Hiromichi Wakui, Kouichi Tamura iD

Kidney360 · 16.11.2026

DOI: 10.34067/kid.0000001468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Kidney360, online erschienen am 16.11.2026. Verfasst von Kazuhiko Shibata und 9 weiteren Autor:innen. Beteiligte Einrichtung: Yokohama City University School of Medicine, Yokohama, Japan. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Objective fluid assessment in hemodialysis often requires dedicated bioimpedance equipment. The Laboratory-Data Integrated Fluid Targeting algorithm uses routine biochemical and dialysis treatment data to estimate extracellular water, intracellular water, and euvolemic body weight. We evaluated its concordance with the Fresenius Body Composition Monitor and explored determinants of method differences.

Methods

In this prospective single-center study, 61 adults receiving stable maintenance hemodialysis for at least 3 months underwent paired assessment during one dialysis session. Agreement was evaluated using Pearson correlation, Deming regression, and Bland–Altman analysis. Exploratory multivariable models were used to examine age, sex, dialysis vintage, diabetes, heart failure, and ischemic heart disease. Clinically prescribed dry weight was analyzed as a separate clinical comparator.

Results

Extracellular-water estimates were strongly correlated (correlation coefficient, 0.87). The mean difference between the Laboratory-Data Integrated Fluid Targeting and Body Composition Monitor estimates was +0.22 L, with 95% limits of agreement from −4.1 to +4.6 L. The correlation for intracellular water was lower (correlation coefficient, 0.80), with a mean difference of +2.7 L and limits of agreement from −3.5 to +8.9 L. Estimated euvolemic weight was strongly correlated (correlation coefficient, 1.0 after rounding), although this partly reflected the shared body-weight component (mean difference, −0.67 kg; limits of agreement, −4.0 to +2.6 kg). Older age was associated with a smaller extracellular-water difference, whereas sex, dialysis vintage, diabetes, heart failure, and ischemic heart disease were not independently associated with method differences.

Conclusions

The laboratory-based algorithm approximated Body Composition Monitor outputs at the cohort level; however, proportional bias and wide individual limits, particularly for intracellular water, preclude interchangeability. These findings support method concordance but do not constitute independent physiological or outcome validation. Clinical actionability and outcome benefit remain untested.

Autor:innen und Institutionen

  • Yokohama City University School of Medicine, Yokohama, Japan.
  • Toshin Clinic, Yokohama, Japan.
  • Chuo Jin Clinic, Kumamoto, Japan.
  • Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Japan.
  • Nagoya Industries Promotion Corporation, Nagoya, Japan.
  • Artisan Lab Co., Ltd., Tokyo, Japan.

ORCID-Profile: Kazuhiko Shibata, Kouichi Tamura

Zitieren

APA

Shibata, K., Fukui, H., Iwamoto, T., Saka, S., Kawai, Y., Aoki, T., Shibata, R., Maeda, K., Wakui, H., & Tamura, K. (2026). Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis. Kidney360. https://doi.org/10.34067/kid.0000001468

Vancouver

Shibata K, Fukui H, Iwamoto T, Saka S, Kawai Y, Aoki T, et al. Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis. Kidney360. 2026. doi:10.34067/kid.0000001468

BibTeX
@article{Shibata2026,
  author = {Shibata, Kazuhiko and Fukui, Hiroyoshi and Iwamoto, Tamio and Saka, Sanae and Kawai, Yuki and Aoki, Takeshi and Shibata, Ryo and Maeda, Kanenori and Wakui, Hiromichi and Tamura, Kouichi},
  title = {Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis},
  journal = {Kidney360},
  year = {2026},
  doi = {10.34067/kid.0000001468}
}
Kostenlos starten →