EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Contemporary Comparison between the Hemodialysis Reliable Outflow Device and Femoral Arteriovenous Graft

Hind Anan iD, Amaan Rahman iD, Elonay Yehualashet, Jacob Weineberg iD, Theodore H Yuo iD

Kidney360 · 2026-08 · 7 (8) · 1807-1814

DOI: 10.34067/kid.0000001210 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Kidney360, online erschienen am 05.05.2026. Verfasst von Hind Anan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular Surgery, Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania. Hauptthemen laut MEDLINE: Renal Dialysis, Arteriovenous Shunt, Surgical, Femoral Artery, Femoral Vein. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Key Points Previously, femoral arteriovenous grafts were the standard approach for patients with upper extremity central venous occlusion. In our study, hemodialysis reliable outflow offered a higher likelihood of obtaining functional patency and fewer complications compared with femoral arteriovenous graft. These findings highlight that hemodialysis reliable outflow graft is a viable option for patients who have exhausted upper extremity arteriovenous access.

Background

Hemodialysis reliable outflow (HeRO) graft and femoral arteriovenous graft (fAVG) are alternative options for patients who have exhausted upper extremity arteriovenous access because of central venous occlusion. This study aims to provide a contemporary comparison between HeRO and fAVG.

Methods

Retrospective chart review of consecutive fAVG and HeRO placed between 2016 and 2023 at a multihospital health care system was conducted. Patients were identified using the local Vascular Quality Initiative database and supplemented by charts review. Baseline characteristics, operative details, and follow-up data were obtained. Data were analyzed using standard statistical tests, Kaplan–Meier survival analysis, and multivariate Cox proportional hazards.

Results

Data for 114 access were collected (68 HeRO, 46 fAVG) from 105 unique patients. Patients receiving HeRO graftswere older (66.1 versus 57.7 years), had higher body mass index (31.8 versus 27.9 kg/m 2 ), and were more likely to have a history of atrial fibrillation (56% versus 20%) and fewer previous arteriovenous accesses (mean 1.4 versus 2.4). The ability to use the graft for hemodialysis was higher in the HeRO group (94% versus 83%; P = 0.049). At 36 months, the primary patency rate was 5% for the HeRO graft and 17% for the fAVG ( P = 0.45), while the secondary patency rates were 30% and 54% ( P = 0.25), respectively. Thrombosis was the predominant cause of HeRO graft abandonment (78%), whereas infection was most common for fAVGs (44%). On Kaplan‑Meier analysis, mortality was similar for HeRO graft and fAVG ( P = 0.22). Six (9%) patients from the HeRO group and ten (22%) from the fAVG group underwent graft removal because of infection ( P = 0.05). The rate of steal did not differ between both groups (HeRO 6% versus fAVG 11%; P = 0.33); however, among patients receiving fAVG, two required access ligation and two underwent limb amputation (HeRO, 0% versus fAVG, 9%; P = 0.01).

Conclusions

HeRO graft is a reasonable alternative for patients who have exhausted upper extremity arteriovenous access, offering a higher likelihood of obtaining functional patency and fewer complications compared with fAVG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisArteriovenous Shunt, SurgicalFemoral ArteryFemoral VeinBlood Vessel Prosthesis ImplantationKidney Failure, ChronicHumansRetrospective StudiesFemaleVascular PatencyMaleMiddle AgedAgedKaplan-Meier EstimateGraft Occlusion, Vascular

Stichwörter der Autor:innen

dialysis accesshemodialysishemodialysis accessmortality

Autor:innen und Institutionen

  • Division of Vascular Surgery, Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.
  • University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.
  • Geisinger Commonwealth School of Medicine, Scranton, Pennsylvania.

ORCID-Profile: Hind Anan, Amaan Rahman, Jacob Weineberg, Theodore H Yuo

Zitieren

APA

Anan, H., Rahman, A., Yehualashet, E., Weineberg, J., & Yuo, T. H. (2026). Contemporary Comparison between the Hemodialysis Reliable Outflow Device and Femoral Arteriovenous Graft. Kidney360, 7(8), 1807-1814. https://doi.org/10.34067/kid.0000001210

Vancouver

Anan H, Rahman A, Yehualashet E, Weineberg J, Yuo TH. Contemporary Comparison between the Hemodialysis Reliable Outflow Device and Femoral Arteriovenous Graft. Kidney360. 2026;7(8):1807-1814. doi:10.34067/kid.0000001210

BibTeX
@article{Anan2026,
  author = {Anan, Hind and Rahman, Amaan and Yehualashet, Elonay and Weineberg, Jacob and Yuo, Theodore H},
  title = {Contemporary Comparison between the Hemodialysis Reliable Outflow Device and Femoral Arteriovenous Graft},
  journal = {Kidney360},
  year = {2026},
  volume = {7},
  number = {8},
  pages = {1807--1814},
  doi = {10.34067/kid.0000001210}
}
Kostenlos starten →