The Role of High-Frequency Wall Vibrations in Adverse Vascular Remodeling of Arteriovenous Fistula for Hemodialysis
Kidney360 · 2026
DOI: 10.34067/kid.0000001112 ↗Kurz gefasst
Fachartikel in der Zeitschrift Kidney360, 2026. Verfasst von Luca Soliveri und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy. Hauptthemen laut MEDLINE: Renal Dialysis, Vibration, Arteriovenous Shunt, Surgical, Vascular Remodeling. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Key Points Flow-induced high-frequency vascular vibrations, computed through fluid-structure interaction simulations, are associated with fistula complications. The association between vibrations and arteriovenous fistula complications suggests a potential new mechanism responsible for vascular remodeling. The frequency and amplitude of vibrations are potential biomarkers for arteriovenous fistula surveillance.
Background
Despite progress in research, the mechanobiological mechanisms behind adverse vascular remodeling and failure in arteriovenous fistula (AVF) for hemodialysis remain unclear. The aim of this investigation was to assess the association between flow-induced vascular wall vibrations and adverse vascular remodeling in AVFs.
Methods
Six ESKD patients with native distal radio-cephalic AVF were monitored for 1 year with magnetic resonance imaging and Doppler ultrasound examinations. Patients were divided based on AVF outcomes: two maintained proper AVF patency and four developed complications (two venous stenoses and two excessive dilatations). Patient-specific fluid-structure interaction simulations were performed at different time points.
Results
Before vascular remodeling, stenotic AVFs exhibited two dominant frequency bands, between 45 and 100 Hz, while excessively dilated AVFs exhibited a single band at 50 Hz. Before the onset of remodeling, patients with complications exhibited significantly higher vibration amplitude (22.5±5.8 μ m versus 6.6±2.0 μ m, P < 0.01) and high-pass strain ([1.30±0.35] 10 −3 versus [0.30±0.10] 10 −3 , P < 0.01) than those with proper patency. Significant differences in vibration amplitude and high-pass strain were observed between patients with proper patency and those with stenosis ( P < 0.001 and P < 0.01, respectively), and in high-pass strain between patients with preserved patency and those with excessive dilatation ( P < 0.01).
Conclusions
Specific vibration frequencies and amplitude levels appear to be associated with distinct types of vascular remodeling, indicating that they could potentially be biomarkers for AVF surveillance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy.
- Department of Engineering and Applied Sciences, University of Bergamo, Bergamo, Italy.
- Diagnostic Radiology, ASST Papa Giovanni XXIII Hospital, Bergamo, Italy.
- School of Medicine, University of Milano-Bicocca, Milan, Italy.
- Nephrology and Dialysis Unit, ASST Papa Giovanni XXIII Hospital, Bergamo, Italy.
- Department of Management, Information and Production Engineering, University of Bergamo, Bergamo, Italy.
ORCID-Profile: Luca Soliveri, Sofia Poloni, Paolo Brambilla, Simona Zerbi, Giulia Cabrini, Anna Caroli, Andrea Remuzzi, Kristian Valen-Sendstad, Michela Bozzetto
Zitieren
APA
Soliveri, L., Poloni, S., Brambilla, P., Zerbi, S., Cabrini, G., Caroli, A., Remuzzi, A., Valen-Sendstad, K., & Bozzetto, M. (2026). The Role of High-Frequency Wall Vibrations in Adverse Vascular Remodeling of Arteriovenous Fistula for Hemodialysis. Kidney360. https://doi.org/10.34067/kid.0000001112
Vancouver
Soliveri L, Poloni S, Brambilla P, Zerbi S, Cabrini G, Caroli A, et al. The Role of High-Frequency Wall Vibrations in Adverse Vascular Remodeling of Arteriovenous Fistula for Hemodialysis. Kidney360. 2026. doi:10.34067/kid.0000001112
BibTeX
@article{Soliveri2026,
author = {Soliveri, Luca and Poloni, Sofia and Brambilla, Paolo and Zerbi, Simona and Cabrini, Giulia and Caroli, Anna and Remuzzi, Andrea and Valen-Sendstad, Kristian and Bozzetto, Michela},
title = {The Role of High-Frequency Wall Vibrations in Adverse Vascular Remodeling of Arteriovenous Fistula for Hemodialysis},
journal = {Kidney360},
year = {2026},
doi = {10.34067/kid.0000001112}
}
EUVIMED