EUVIMEDEUVIMED entdecken
Open Access

Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid–Structure Interaction Analyses

Masanori Murakami, Fei Jiang, Tatsuo Yamashita, Shinsuke Mochizuki

Annals of Vascular Diseases · 2026 · 19 (1) · n/a

DOI: 10.3400/avd.oa.26-00052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Vascular Diseases, 2026. Verfasst von Masanori Murakami und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, National Hospital Organization Kanmon Medical Center, Shimonoseki, Yamaguchi, Japan. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of this study was to compare the effects of balloon-expandable and self-expanding stents on vessel wall mechanics and hemodynamics in a patient-specific saccular abdominal aortic aneurysm model.

Methods

A patient-specific aneurysm model was constructed using computed tomography images, and balloon-expandable and self-expanding stent models were created. Aortic wall stress was evaluated by contact analysis. Fluid-structure interaction analyses were performed at 5 representative phases selected from the cardiac cycle. Mean intra-aneurysmal flow velocity, wall shear stress (WSS), pressure loss, and energy loss were compared.

Results

The balloon-expandable stent produced greater localized aortic wall stress than the self-expanding stent, whereas wall stress was more uniformly distributed with the self-expanding stent. Both stents reduced the mean intra-aneurysmal flow velocity, WSS, pressure loss, and energy loss compared with the no-stent model. However, greater reductions in WSS, pressure loss, and energy loss were noted with the balloon-expandable stent than with the self-expanding stent.

Conclusions

Balloon-expandable and self-expanding stents exhibited different effects on vessel wall mechanics and hemodynamics. The findings indicate the importance of evaluating both hemodynamic and mechanical effects when assessing stent-vessel interactions.

Schlagwörter

Stichwörter der Autor:innen

abdominal aortic aneurysmballoon-expandable stentfluid–structure interactionhemodynamicsself-expanding stent

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, National Hospital Organization Kanmon Medical Center, Shimonoseki, Yamaguchi, Japan.
  • Department of Mechanical Engineering, Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Ube, Yamaguchi, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Murakami, M., Jiang, F., Yamashita, T., & Mochizuki, S. (2026). Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid–Structure Interaction Analyses. Annals of Vascular Diseases, 19(1), n/a. https://doi.org/10.3400/avd.oa.26-00052

Vancouver

Murakami M, Jiang F, Yamashita T, Mochizuki S. Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid–Structure Interaction Analyses. Annals of Vascular Diseases. 2026;19(1):n/a. doi:10.3400/avd.oa.26-00052

BibTeX
@article{Murakami2026,
  author = {Murakami, Masanori and Jiang, Fei and Yamashita, Tatsuo and Mochizuki, Shinsuke},
  title = {Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid–Structure Interaction Analyses},
  journal = {Annals of Vascular Diseases},
  year = {2026},
  volume = {19},
  number = {1},
  pages = {n/a},
  doi = {10.3400/avd.oa.26-00052}
}
Kostenlos starten →