Two-transducer method for measuring gas pressure pulsation

Steven E Marshall

INTER-NOISE and NOISE-CON Congress and Conference Proceedings · 20.07.2026 · 273 (1) · 1187-1190

DOI: 10.3397/nc_2026_0194 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INTER-NOISE and NOISE-CON Congress and Conference Proceedings, erschienen am 20.07.2026. Verfasst von Steven E Marshall.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pressure pulsation created by a positive-displacement compressors propagate in refrigerant gas and can cause unwanted sound and vibrations from other components adjacent to the compressor. Pulsation level in a gas line is the summation of the progressive and reflected waves. Reflections occur when a progressive wave encounters an impedance discontinuity. Superposition of progressive and reflected waves forms standing wave patterns. A compressor's predisposition to produce unwanted sound is best determined from the amplitude of its progressive wave. Accurate measurement of progressive waves has previously depended on reducing the levels of the reflected waves. For example, the ANSI/AHRI Standard 530-2022 requires that refrigerant lines approximate anechoic terminations. To achieve anechoic conditions, the standard calls for long sections of refrigerant 'coil' to create an anechoic termination. Experience has shown, however, that pulsation waves reflect from the anechoic coils and the two-phase physical fluid state. The approach is presented for using two pressure transducers to measure the levels of a progressive wave buried within reflected wave. The method seeks to separate the progressive wave from the reflected wave using a transfer function analysis. The method provides a promising improvement for inclusion in the next version of AHRI Test Standard 530.

Zitieren

APA

Marshall, S. E. (2026). Two-transducer method for measuring gas pressure pulsation. INTER-NOISE and NOISE-CON Congress and Conference Proceedings, 273(1), 1187-1190. https://doi.org/10.3397/nc_2026_0194

Vancouver

Marshall SE. Two-transducer method for measuring gas pressure pulsation. INTER-NOISE and NOISE-CON Congress and Conference Proceedings. 2026;273(1):1187-1190. doi:10.3397/nc_2026_0194

BibTeX
@article{Marshall2026,
  author = {Marshall, Steven E},
  title = {Two-transducer method for measuring gas pressure pulsation},
  journal = {INTER-NOISE and NOISE-CON Congress and Conference Proceedings},
  year = {2026},
  volume = {273},
  number = {1},
  pages = {1187--1190},
  doi = {10.3397/nc_2026_0194}
}
Kostenlos starten →