EUVIMEDEUVIMED entdecken
Crossref

Coordinated aerodynamic and acoustical performance beyond compliance in data center design

Viken Koukounian, Will Cole, Joseph Horesco

INTER-NOISE and NOISE-CON Congress and Conference Proceedings · 20.07.2026 · 273 (2) · 981-995

DOI: 10.3397/nc_2026_0166 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INTER-NOISE and NOISE-CON Congress and Conference Proceedings, erschienen am 20.07.2026. Verfasst von Viken Koukounian und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In data center development, the aerodynamic and thermal performance of air-cooled chillers, along with their associated acoustical impacts are frequently addressed as separate design exercises, often resulting in reactive mitigation measures and constrained operational flexibility. Although projects may demonstrate compliance with applicable noise ordinances, noise-related complaints can persist, highlighting the distinction between regulatory compliance and community acceptance. This paper proposes a unified, performance-based framework that aligns CFD-driven aerodynamic analysis with detailed acoustical source characterization and attenuation design from project inception. By treating airflow performance, heat rejection, and sound emission as interdependent variables, the approach establishes a replicable methodology applicable to both new construction and retrofit scenarios, where complexity and cost drivers vary but the underlying coordination challenge remains consistent. Through a representative case study, the paper illustrates how integrated modeling informs screening strategies, intake and discharge attenuation decisions, and site-specific risk mitigation. The framework further considers how proactive coordination may reduce downstream retrofits and material redundancy, while acknowledging that non-acoustical factors influencing annoyance extend beyond compliance metrics.

Zitieren

APA

Koukounian, V., Cole, W., & Horesco, J. (2026). Coordinated aerodynamic and acoustical performance beyond compliance in data center design. INTER-NOISE and NOISE-CON Congress and Conference Proceedings, 273(2), 981-995. https://doi.org/10.3397/nc_2026_0166

Vancouver

Koukounian V, Cole W, Horesco J. Coordinated aerodynamic and acoustical performance beyond compliance in data center design. INTER-NOISE and NOISE-CON Congress and Conference Proceedings. 2026;273(2):981-995. doi:10.3397/nc_2026_0166

BibTeX
@article{Koukounian2026,
  author = {Koukounian, Viken and Cole, Will and Horesco, Joseph},
  title = {Coordinated aerodynamic and acoustical performance beyond compliance in data center design},
  journal = {INTER-NOISE and NOISE-CON Congress and Conference Proceedings},
  year = {2026},
  volume = {273},
  number = {2},
  pages = {981--995},
  doi = {10.3397/nc_2026_0166}
}
Kostenlos starten →