Influence of floating floor structures on flanking sound transmission across cross-laminated timber junctions

Stijn Moons, Ashwin Dias, Edwin P.B. Reynders, Reinhilde Lanoye

INTER-NOISE and NOISE-CON Congress and Conference Proceedings · 20.07.2026 · 273 (2) · 752-763

DOI: 10.3397/nc_2026_0118 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INTER-NOISE and NOISE-CON Congress and Conference Proceedings, erschienen am 20.07.2026. Verfasst von Stijn Moons und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Engineered timber materials such as cross-laminated timber (CLT) are experiencing a significant rise in popularity due to their low carbon footprint, low weight and relatively high strength and stiffness. However, their poor intrinsic acoustic performance is a prime challenge for their further adoption. The direct sound transmission through walls or floors can reliably be mitigated with well-tailored wall lining and floating floor solutions. However, the reduction of flanking sound transmission, where vibrational energy is transmitted between walls and/or floors across a common junction, is a major concern. The attenuation of flanking sound between two building elements i and j is quantified by the vibration reduction index Ki j, which can be experimentally determined on-site or in a laboratory in accordance with ISO 10848, currently under revision. This work summarizes the findings of an experimental campaign on a horizontal X-junction made of CLT in a laboratory setting. In particular, Ki j is determined for a junction of bare CLT panels and junctions with a floating floor solution in order to quantify their influence on the mitigation of flanking sound transmission. It was found that the influence on Ki j is quite small and the effect of floating floors should be considered in a broader context of overall sound transmission between rooms, including both direct and indirect transmission paths. While they increase the overall sound reduction index between rooms significantly, they should be used in combination with junction decoupling solutions such as resilient strips for a sufficient overall performance.

Zitieren

APA

Moons, S., Dias, A., Reynders, E. P., & Lanoye, R. (2026). Influence of floating floor structures on flanking sound transmission across cross-laminated timber junctions. INTER-NOISE and NOISE-CON Congress and Conference Proceedings, 273(2), 752-763. https://doi.org/10.3397/nc_2026_0118

Vancouver

Moons S, Dias A, Reynders EP, Lanoye R. Influence of floating floor structures on flanking sound transmission across cross-laminated timber junctions. INTER-NOISE and NOISE-CON Congress and Conference Proceedings. 2026;273(2):752-763. doi:10.3397/nc_2026_0118

BibTeX
@article{Moons2026,
  author = {Moons, Stijn and Dias, Ashwin and Reynders, Edwin P.B. and Lanoye, Reinhilde},
  title = {Influence of floating floor structures on flanking sound transmission across cross-laminated timber junctions},
  journal = {INTER-NOISE and NOISE-CON Congress and Conference Proceedings},
  year = {2026},
  volume = {273},
  number = {2},
  pages = {752--763},
  doi = {10.3397/nc_2026_0118}
}