Comparison of two experimental methods for characterizing a preloaded metal spring
INTER-NOISE and NOISE-CON Congress and Conference Proceedings · 20.07.2026 · 273 (2) · 423-431
DOI: 10.3397/nc_2026_0074 ↗Kurz gefasst
Fachartikel in der Zeitschrift INTER-NOISE and NOISE-CON Congress and Conference Proceedings, erschienen am 20.07.2026. Verfasst von David Neihguk und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Two experimental methods are evaluated for characterizing a preloaded helical steel spring. The first method applies axial static preload using freely suspended weights transmitted through the center of rigid end fixtures. The second method applies preload with a monofilament nylon string in parallel with the spring, providing an independent configuration for comparison. In both methods, impact testing is used to measure frequency response functions, which are converted to virtual points using virtual point transformation. Inverse substructuring is then applied to extract the six degree-of-freedom (DoF) transfer dynamic stiffness of the metal spring. The comparison provides experimental evidence on the robustness of six DoF dynamic stiffness characterization under axial preload using a preload.
Zitieren
APA
Neihguk, D., Herrin, D. W., & Klerk, D. D. (2026). Comparison of two experimental methods for characterizing a preloaded metal spring. INTER-NOISE and NOISE-CON Congress and Conference Proceedings, 273(2), 423-431. https://doi.org/10.3397/nc_2026_0074
Vancouver
Neihguk D, Herrin DW, Klerk DD. Comparison of two experimental methods for characterizing a preloaded metal spring. INTER-NOISE and NOISE-CON Congress and Conference Proceedings. 2026;273(2):423-431. doi:10.3397/nc_2026_0074
BibTeX
@article{Neihguk2026,
author = {Neihguk, David and Herrin, David W. and Klerk, Dennis De},
title = {Comparison of two experimental methods for characterizing a preloaded metal spring},
journal = {INTER-NOISE and NOISE-CON Congress and Conference Proceedings},
year = {2026},
volume = {273},
number = {2},
pages = {423--431},
doi = {10.3397/nc_2026_0074}
}