EUVIMEDEUVIMED entdecken
Crossref

First-in-Central-Europe implantation of the self-expandable Pulsta valve in pulmonary position: Short-term results

Sara Korabiewska-Pluta, Krzysztof Michalak, Joanna Młodawska, Monika Łubisz, Grażyna Brzezińska-Rajszys, Adam Koleśnik, Mario Carminati, Tomasz Moszura

Polish Heart Journal · 2024

DOI: 10.33963/v.phj.103312 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polish Heart Journal, 2024. Verfasst von Sara Korabiewska-Pluta und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Polish-Mother's Memorial Hospital Research Institute, Łódź, Poland. sara.korabiewska@gmail.com. Hauptthemen laut MEDLINE: Pulmonary Valve, Tetralogy of Fallot, Pulmonary Valve Insufficiency, Heart Valve Prosthesis.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Tetralogy of Fallot after complete correction constantly presents potential challenges in pediatric cardiology. In particular, patients with pulmonary regurgitation require ongoing monitoring, reoperation, or catheter intervention during adolescence. The increasing demand for a wide spectrum of sizes and shapes of implantable prostheses led to the development of the self-expanding Pulsta® valve. AIMS: In this study, we evaluated postprocedural outcomes, focusing on pulmonary valve functionality and right ventricular (RV) parameters, using advanced echocardiographic techniques. METHODS: We reviewed five pediatric patients before and over a 6-month follow-up period after the procedure using three-dimensional echocardiography acquisition (3D transthoracic echocardiography), RV global longitudinal strain, and tissue Doppler imaging. RESULTS: All procedures were successful, with good early effects and no complications. Postprocedural assessment of RV diameter and volume showed a statistically significant reduction, and this trend continued during the follow-up period. However, in this cohort, RV ejection fraction, which was initially within the normal range, showed a slight reduction immediately after the procedure, followed by a gradual return to normal values during the follow-up. Similar statistically significant results in RV strain values were observed. CONCLUSION: In the study group, the Pulsta® valve provided good early-term effectiveness and feasibility without adverse events, and the overall mortality rate was 0%, highlighting the potential benefits of this intervention as measured by echocardiographic parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary ValveTetralogy of FallotPulmonary Valve InsufficiencyHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMaleFemaleTreatment OutcomeChildAdolescentEchocardiography, Three-DimensionalChild, Preschool

Stichwörter der Autor:innen

pediatricpercutaneous pulmonary valve implantationpulmonary valve diseaseright ventricular outflow tractstent valve

Autor:innen und Institutionen

  • Department of Cardiology, Polish-Mother's Memorial Hospital Research Institute, Łódź, Poland. sara.korabiewska@gmail.com.
  • Department of Cardiology, Polish-Mother's Memorial Hospital Research Institute, Łódź, Poland.
  • Cardiovascular Interventional Laboratory, The Children's Memorial Health Institute, Warszawa, Poland.
  • Department of Pediatric and Adult Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico, San Donato Milanese, Italy.

Zitieren

APA

Korabiewska-Pluta, S., Michalak, K., Młodawska, J., Łubisz, M., Brzezińska-Rajszys, G., Koleśnik, A., Carminati, M., & Moszura, T. (2024). First-in-Central-Europe implantation of the self-expandable Pulsta valve in pulmonary position: Short-term results. Polish Heart Journal. https://doi.org/10.33963/v.phj.103312

Vancouver

Korabiewska-Pluta S, Michalak K, Młodawska J, Łubisz M, Brzezińska-Rajszys G, Koleśnik A, et al. First-in-Central-Europe implantation of the self-expandable Pulsta valve in pulmonary position: Short-term results. Polish Heart Journal. 2024. doi:10.33963/v.phj.103312

BibTeX
@article{KorabiewskaPluta2024,
  author = {Korabiewska-Pluta, Sara and Michalak, Krzysztof and Młodawska, Joanna and Łubisz, Monika and Brzezińska-Rajszys, Grażyna and Koleśnik, Adam and Carminati, Mario and Moszura, Tomasz},
  title = {First-in-Central-Europe implantation of the self-expandable Pulsta valve in pulmonary position: Short-term results},
  journal = {Polish Heart Journal},
  year = {2024},
  doi = {10.33963/v.phj.103312}
}
Kostenlos starten →