EUVIMEDEUVIMED entdecken
Crossref

Validity of the Pneumonitor for RR intervals acquisition for short-term heart rate variability analysis extended with respiratory data in pediatric cardiac patients

Jakub S Gąsior, Marcel Młyńczak, Maciej Rosoł, Piotr Wieniawski, Iwona Walecka, Gerard Cybulski, Bożena Werner

Kardiologia Polska · 2023

DOI: 10.33963/kp.a2023.0070 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Kardiologia Polska, 2023. Verfasst von Jakub S Gąsior und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warszawa, Poland. jakub.gasior@wum.edu.pl. Hauptthemen laut MEDLINE: Respiratory Rate, Heart Diseases. Die Arbeit wurde bisher 10-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Breathing pattern alterations change the variability and spectral content of the RR intervals (RRi) on electrocardiogram (ECG). However, there is no method to record and control participants' breathing without influencing its natural rate and depth in heart rate variability (HRV) studies. AIM: This study aimed to assess the validity of the Pneumonitor for acquisition of short-term (5 minutes) RRi in comparison to the reference ECG method for analysis of heart rate (HR) and HRV parameters in the group of pediatric patients with cardiac disease. METHODS: Nineteen patients of both sexes participated in the study. An ECG and Pneumonitor were used to record RRi in 5-minute static rest conditions, the latter also to measure the relative tidal volume and respiratory rate. The validation comprised Student's t-test, Bland-Altman analysis, intraclass correlation coefficient, and Lin's concordance correlation. The possible impact of respiratory activity on the agreement between ECG and the Pneumonitor was also assessed. RESULTS: An acceptable agreement for the number of RRi, mean RR, hazard ratio (HR), and HRV measures calculated based on RRi acquired using the ECG and Pneumonitor was presented. There was no association between the breathing pattern and RRi agreement between devices. CONCLUSIONS: The Pneumonitor might be considered appropriate for cardiorespiratory studies in the group of pediatric cardiac patients in rest condition.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiratory RateHeart DiseasesMaleFemaleHumansChildHeart RateElectrocardiographyReproducibility of Results

Stichwörter der Autor:innen

PneumonitorRR intervalsheart rate variabilityimpedance pneumographyvalidation

Autor:innen und Institutionen

  • Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warszawa, Poland. jakub.gasior@wum.edu.pl.
  • Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warszawa, Poland.
  • Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warszawa, Poland.
  • Department of Pediatric Cardiology and General Pediatrics, Doctoral School Medical University of Warsaw, Warszawa, Poland.

Zitieren

APA

Gąsior, J. S., Młyńczak, M., Rosoł, M., Wieniawski, P., Walecka, I., Cybulski, G., & Werner, B. (2023). Validity of the Pneumonitor for RR intervals acquisition for short-term heart rate variability analysis extended with respiratory data in pediatric cardiac patients. Kardiologia Polska. https://doi.org/10.33963/kp.a2023.0070

Vancouver

Gąsior JS, Młyńczak M, Rosoł M, Wieniawski P, Walecka I, Cybulski G, et al. Validity of the Pneumonitor for RR intervals acquisition for short-term heart rate variability analysis extended with respiratory data in pediatric cardiac patients. Kardiologia Polska. 2023. doi:10.33963/kp.a2023.0070

BibTeX
@article{Gsior2023,
  author = {Gąsior, Jakub S and Młyńczak, Marcel and Rosoł, Maciej and Wieniawski, Piotr and Walecka, Iwona and Cybulski, Gerard and Werner, Bożena},
  title = {Validity of the Pneumonitor for RR intervals acquisition for short-term heart rate variability analysis extended with respiratory data in pediatric cardiac patients},
  journal = {Kardiologia Polska},
  year = {2023},
  doi = {10.33963/kp.a2023.0070}
}
Kostenlos starten →