Optimal Fractional-Order Backstepping Control of Dual-Star Induction Generator Wind Energy Conversion Systems Under Wind and Parameter Uncertainties
Wind · 22.10.2026 · 6 (4) · 63
DOI: 10.3390/wind6040063 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wind, online erschienen am 22.10.2026. Verfasst von Abdessmad Milles und 3 weiteren Autor:innen. Die Arbeit nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EU Clean Energy Transition Partnership, Unitatea Executiva Pentru Finantarea Invatamantului Superior Si A Cercetarii Stiintifice Universitare.
Abstract (Originalsprache)
Wind energy conversion systems based on dual-star induction generators (DSIGs) exhibit nonlinear dynamics and sensitivity to operating-condition variations, which can adversely affect power tracking, DC-link voltage regulation, and power quality. This study proposes a fractional-order backstepping control strategy optimized by the Ant Lion Optimizer (FOBC-ALO) for a DSIG-based wind energy conversion system. The fractional-order formulation provides an additional degree of freedom for shaping the controller response, while the ALO algorithm is employed to optimize the controller gains. The fractional order is selected through a sensitivity analysis, with α = 0.5 providing the most balanced performance among tracking accuracy, transient response, DC-link voltage regulation, and harmonic distortion. The proposed controller was implemented and evaluated in MATLAB 2021/Simulink and compared with a conventional backstepping controller under four simulation scenarios involving variable wind-speed profiles, machine-parameter variations, stepwise wind-speed changes, and operation without maximum power point tracking. The results show that the proposed controller consistently improves the dynamic and power-quality performance of the DSIG-based system. In the first test, the active-power response time was reduced from 1.66 to 1.32 ms, while the current total harmonic distortion (THD) decreased from 1.87% to 1.06%. Under 100% variations in the selected machine parameters, the THD decreased from 5.13% to 2.13%, while the DC-link voltage fluctuation was reduced from 10.18 to 3.02 V. For the stepwise wind-speed test, the proposed controller reduced the active-power response time by 47.99%, the ITAE by 63.70%, the DC-link voltage fluctuation by 71.90%, and the current THD by 48.69%. In the operation without MPPT, the integral of time multiplied by squared error (ITSE), integral of time multiplied by absolute error (ITAE), DC-link voltage ripple, and current THD were reduced by 41.28%, 57.67%, 74.88%, and 46.94%, respectively. Overall, the simulation results indicate that the proposed FOBC-ALO strategy improves reference tracking, transient response, DC-link voltage regulation, and current waveform quality across the investigated operating conditions. The findings provide a simulation-based foundation for subsequent real-time and experimental validation of fractional-order control for DSIG-based wind energy conversion systems.
Förderung
- EU Clean Energy Transition Partnership
- Unitatea Executiva Pentru Finantarea Invatamantului Superior Si A Cercetarii Stiintifice Universitare
Zitieren
APA
Milles, A., Benbouhenni, H., Bizon, N., & Tulbure, A. (2026). Optimal Fractional-Order Backstepping Control of Dual-Star Induction Generator Wind Energy Conversion Systems Under Wind and Parameter Uncertainties. Wind, 6(4), 63. https://doi.org/10.3390/wind6040063
Vancouver
Milles A, Benbouhenni H, Bizon N, Tulbure A. Optimal Fractional-Order Backstepping Control of Dual-Star Induction Generator Wind Energy Conversion Systems Under Wind and Parameter Uncertainties. Wind. 2026;6(4):63. doi:10.3390/wind6040063
BibTeX
@article{Milles2026,
author = {Milles, Abdessmad and Benbouhenni, Habib and Bizon, Nicu and Tulbure, Adrian},
title = {Optimal Fractional-Order Backstepping Control of Dual-Star Induction Generator Wind Energy Conversion Systems Under Wind and Parameter Uncertainties},
journal = {Wind},
year = {2026},
volume = {6},
number = {4},
pages = {63},
doi = {10.3390/wind6040063}
}
EUVIMED