Kurz gefasst

Fachartikel in der Zeitschrift Wind, online erschienen am 18.05.2026. Verfasst von Konrad M. Hartung und 2 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry for Economic Affairs and Climate Action.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates whether aerodynamic interaction effects in an interlocked (negative-gap) counter-rotating dual Savonius rotor configuration can improve the efficiency of drag-based vertical-axis wind turbines in urban wind conditions. Two-dimensional Computational Fluid Dynamics (CFD) simulations were performed in ANSYS Fluent 2025 R2 using both steady and unsteady RANS approaches, including dynamic meshing to enable collision-free rotation in the interlocked overlap region. The numerical setup was first validated for a single two-bucket reference rotor against published experimental data of torque and power coefficients and subsequently applied to dual-rotor configurations with negative gap distances. The results show that the dual-rotor arrangement redistributes torque production over the azimuth angle and yields a smoother and consistently positive mean static torque coefficient, indicating improved self-starting behavior compared to the single rotor. Under transient operation, the dual-rotor configuration yields higher power coefficient values across the entire investigated tip-speed ratio range. The highest performance gain is observed at a tip-speed ratio of λ≈1.0, where the peak power coefficient increases from cp≈0.25 (single-rotor) to cp≈0.32 (dual-rotor), corresponding to an improvement of the power coefficient of about Δcp/cp0≈28%.

Förderung

  • Federal Ministry for Economic Affairs and Climate Action

Zitieren

APA

Hartung, K. M., Stumpe, M., & Oehlert, K. (2026). CFD Analysis and Performance Evaluation of an Interlocked (Negative-Gap) Savonius Dual-Rotor Configuration. Wind, 6(2), 23. https://doi.org/10.3390/wind6020023

Vancouver

Hartung KM, Stumpe M, Oehlert K. CFD Analysis and Performance Evaluation of an Interlocked (Negative-Gap) Savonius Dual-Rotor Configuration. Wind. 2026;6(2):23. doi:10.3390/wind6020023

BibTeX
@article{Hartung2026,
  author = {Hartung, Konrad M. and Stumpe, Marvin and Oehlert, Karsten},
  title = {CFD Analysis and Performance Evaluation of an Interlocked (Negative-Gap) Savonius Dual-Rotor Configuration},
  journal = {Wind},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {23},
  doi = {10.3390/wind6020023}
}