Design and Field Validation of a Low-Cost IoT-Enabled Smart Boat for Real-Time Urban Water Quality Monitoring
Water · 20.11.2026 · 18 (22) · 2903
DOI: 10.3390/w18222903 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water, online erschienen am 20.11.2026. Verfasst von Mirza Md Tasnim Mukarram und 3 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Saud University, The Military Institute of Science and Technology.
Abstract (Originalsprache)
Urban water managers in resource-limited settings need spatially distributed, near-real-time water quality data, yet affordable mobile platforms validated against reference measurements at the density that management use requires remain scarce. We report the design, construction, and field validation of a low-cost Internet of Things (IoT)-enabled unmanned surface vehicle, the smart boat, which carries pH, water temperature, turbidity, and nitrate sensors with an IP camera and Bluetooth and GSM/GPRS telemetry for USD 600 in hardware. We validated it at 61 stations in BUP Lake, Dhaka, Bangladesh, with eight reference samples per 140 min occupation (488 pairs per parameter) and repeated-measures agreement methods. Root mean square error was 0.148 pH, 0.265 °C, 2.208 NTU, and 0.660 mg/L. With stations as the resampling unit, slope intervals included unity for all four parameters, and the Deming interval excluded unity only for turbidity. A mixed-effects decomposition attributed 95 to 99% of the variance in the device-reference difference to between-station offsets. A global linear correction evaluated on withheld stations removed mean bias but left RMSE unchanged, whereas a one-point offset from the first reference pair at a station, applied to the remaining pairs of the same occupation, reduced RMSE by 70 to 89%. The five-year cost of ownership is USD 1968. Under an equivalent workload, screening with 10% confirmatory laboratory samples costs 86% less than a conventional laboratory program, and station-referenced monitoring costs 75% less with a portable field kit and 8% less with laboratory samples at every visit. Within the validated envelope of one warm urban lake, the platform serves screening and spatial reconnaissance with a reference pair at each station visit; it is not a tool for regulatory reporting.
Förderung
- King Saud University
- The Military Institute of Science and Technology
Zitieren
APA
Mukarram, M. M. T., Kafy, A. A., Hossain, M. I., & Altuwaijri, H. A. (2026). Design and Field Validation of a Low-Cost IoT-Enabled Smart Boat for Real-Time Urban Water Quality Monitoring. Water, 18(22), 2903. https://doi.org/10.3390/w18222903
Vancouver
Mukarram MMT, Kafy AA, Hossain MI, Altuwaijri HA. Design and Field Validation of a Low-Cost IoT-Enabled Smart Boat for Real-Time Urban Water Quality Monitoring. Water. 2026;18(22):2903. doi:10.3390/w18222903
BibTeX
@article{Mukarram2026,
author = {Mukarram, Mirza Md Tasnim and Kafy, Abdulla Al and Hossain, Md. Iquebal and Altuwaijri, Hamad Ahmed},
title = {Design and Field Validation of a Low-Cost IoT-Enabled Smart Boat for Real-Time Urban Water Quality Monitoring},
journal = {Water},
year = {2026},
volume = {18},
number = {22},
pages = {2903},
doi = {10.3390/w18222903}
}
EUVIMED