Charging, Generation, and PID Control-Activation Characteristics of a One-Pipe–Two-Unit Hydraulic Short-Circuit Pumped-Storage System: A Simulation Case Study

Fei Zhang, Jing Fu, Faye Jin, Xueli An

Water · 21.08.2026 · 18 (16) · 2052

DOI: 10.3390/w18162052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water, online erschienen am 21.08.2026. Verfasst von Fei Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Corporation of China Headquarters Science and Technology Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the limited pumping-mode flexibility of fixed-speed pumped-storage units, this paper presents a simulation case study of a one-pipe–two-unit parallel ternary system developed in OpenModelica and coupled with Python 3.7. The study examines pure charging and generation, hydraulic short-circuit (HSC) charging, and the PID control-activation transient at nominal speed. A 50 MW benchmark reproduces published pump and turbine shaft powers to within approximately 0.5%, while the system-efficiency difference is 0.14 percentage points, supporting implementation consistency; no plant-measurement validation is claimed. Dual-pump operation reduces the charging time by approximately 44% relative to single-pump operation but lowers efficiency, whereas dual-turbine operation is slightly more efficient because of improved per-unit flow matching. Across the full-cycle HSC sweep, average efficiency increases from 38.6% at 40 MW to 74.1% at 90 MW as internal recirculation decreases. In the PID sensitivity screen, the proportional gain k has the largest effect on the response, a small integral time Ti amplifies sensitivity to k and can increase overshoot or hydraulic loading, and the derivative coefficient wd has only a minor effect within the tested range. The numerical bounds are specific to the selected characteristic maps, reservoir, and waterway; the results are intended as retrofit-screening guidance rather than universal design limits.

Förderung

  • State Grid Corporation of China Headquarters Science and Technology Project

Zitieren

APA

Zhang, F., Fu, J., Jin, F., & An, X. (2026). Charging, Generation, and PID Control-Activation Characteristics of a One-Pipe–Two-Unit Hydraulic Short-Circuit Pumped-Storage System: A Simulation Case Study. Water, 18(16), 2052. https://doi.org/10.3390/w18162052

Vancouver

Zhang F, Fu J, Jin F, An X. Charging, Generation, and PID Control-Activation Characteristics of a One-Pipe–Two-Unit Hydraulic Short-Circuit Pumped-Storage System: A Simulation Case Study. Water. 2026;18(16):2052. doi:10.3390/w18162052

BibTeX
@article{Zhang2026,
  author = {Zhang, Fei and Fu, Jing and Jin, Faye and An, Xueli},
  title = {Charging, Generation, and PID Control-Activation Characteristics of a One-Pipe–Two-Unit Hydraulic Short-Circuit Pumped-Storage System: A Simulation Case Study},
  journal = {Water},
  year = {2026},
  volume = {18},
  number = {16},
  pages = {2052},
  doi = {10.3390/w18162052}
}