Hydrodynamic Roof-Impact Pressure Induced by Water Sloshing in High-Filling Rectangular Storage Tanks: Shaking-Table Tests and Experimentally Calibrated Prediction
Water · 05.08.2026 · 18 (15) · 1911
DOI: 10.3390/w18151911 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water, online erschienen am 05.08.2026. Verfasst von Haoran Qin und 1 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Beijing University of Civil Engineering and Architecture, National Natural Science Foundation of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Large-amplitude water sloshing in high-filling storage tanks can generate transient roof-impact pressures that threaten structural safety and operational reliability. This study develops a simplified momentum-conservation-based model for estimating the maximum dynamic impact pressure (MDIP) in rectangular tanks. The impact load is represented by the rate of momentum change within the roof-wetted liquid region, and the model parameters are calibrated using shaking-table tests. A total of 130 sinusoidal-excitation cases covering three filling depths and multiple excitation frequencies and amplitudes were conducted. The experimental results indicate that the roof-pressure response is strongly non-sinusoidal, with short-duration impulsive peaks and pronounced cycle-to-cycle variability. In the representative cases, the MDIP occurs after the first roof-contact event and varies non-monotonically with excitation amplitude. After calibration, the model provides reasonable estimates of the measured MDIP for most test conditions. The proposed formulation is physically interpretable and computationally efficient, making it suitable for rapid preliminary estimation of sloshing-induced roof-impact pressure in high-filling rectangular water tanks.
Förderung
- Beijing University of Civil Engineering and Architecture
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
Zitieren
APA
Qin, H., & Wang, J. (2026). Hydrodynamic Roof-Impact Pressure Induced by Water Sloshing in High-Filling Rectangular Storage Tanks: Shaking-Table Tests and Experimentally Calibrated Prediction. Water, 18(15), 1911. https://doi.org/10.3390/w18151911
Vancouver
Qin H, Wang J. Hydrodynamic Roof-Impact Pressure Induced by Water Sloshing in High-Filling Rectangular Storage Tanks: Shaking-Table Tests and Experimentally Calibrated Prediction. Water. 2026;18(15):1911. doi:10.3390/w18151911
BibTeX
@article{Qin2026,
author = {Qin, Haoran and Wang, Jishuai},
title = {Hydrodynamic Roof-Impact Pressure Induced by Water Sloshing in High-Filling Rectangular Storage Tanks: Shaking-Table Tests and Experimentally Calibrated Prediction},
journal = {Water},
year = {2026},
volume = {18},
number = {15},
pages = {1911},
doi = {10.3390/w18151911}
}
EUVIMED