EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydraulic Performance and Ship Safety Assessment of an Auxiliary Lock System Under Rapidly Varying Downstream Water Levels

Lei Wang, Chao Guo, Zhanhui Liu, Yaan Hu, Yongle Li, Zhonghua Li, Muhammad Shahid Khan

Water · 21.07.2026 · 18 (14) · 1756

DOI: 10.3390/w18141756 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water, online erschienen am 21.07.2026. Verfasst von Lei Wang und 6 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Foreign Expert Project of China, National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapidly varying downstream water levels induced by hydropower regulation and emergency shutdowns pose significant hydraulic challenges for safe vessel passage through ship-lift systems. This study investigates the hydraulic performance and navigational safety of an auxiliary lock chamber designed to buffer such fluctuations at the Baise ship lift on the Youjiang River, Guangxi, China. A centralized water filling/emptying system combining flat-gate bottom inflow with grid-based energy dissipation was evaluated through an integrated methodology comprising a one-dimensional unsteady flow mathematical model and a 1:30-scale physical hydraulic model. Under the design condition (H = 3.0 m), through the recommended gate-opening speed, the filling time is 239 s with a peak discharge of 162.41 m3/s; the corresponding emptying time is 229 s with a peak discharge of 163.22 m3/s. Under the normal condition (H = 1.5 m), the filling time is 214 s with a peak discharge of 85.57 m3/s. A staged gate-opening strategy at a controlled speed of 1 m/min, with vessel-type-specific stopping elevations and water-level equalization before full opening, ensures that mooring forces remain within regulatory limits under all conditions. Under the extreme condition (H = 5.64 m), the maximum longitudinal mooring force is 31.80 kN for a 1000 t vessel (allowable: 32 kN) and 24.66 kN for a 2 × 500 t fleet (allowable: 25 kN); without the staged protocol, forces reaching 88.71 kN were measured. Inlet conduit pressure measurements under the governing extreme-head scenario confirm no subatmospheric conditions. The findings provide validated operational guidance for auxiliary lock design in high-head navigation structures to rapidly varying downstream water levels.

Förderung

  • Foreign Expert Project of China
  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • China Postdoctoral Science Foundation

Zitieren

APA

Wang, L., Guo, C., Liu, Z., Hu, Y., Li, Y., Li, Z., & Khan, M. S. (2026). Hydraulic Performance and Ship Safety Assessment of an Auxiliary Lock System Under Rapidly Varying Downstream Water Levels. Water, 18(14), 1756. https://doi.org/10.3390/w18141756

Vancouver

Wang L, Guo C, Liu Z, Hu Y, Li Y, Li Z, et al. Hydraulic Performance and Ship Safety Assessment of an Auxiliary Lock System Under Rapidly Varying Downstream Water Levels. Water. 2026;18(14):1756. doi:10.3390/w18141756

BibTeX
@article{Wang2026,
  author = {Wang, Lei and Guo, Chao and Liu, Zhanhui and Hu, Yaan and Li, Yongle and Li, Zhonghua and Khan, Muhammad Shahid},
  title = {Hydraulic Performance and Ship Safety Assessment of an Auxiliary Lock System Under Rapidly Varying Downstream Water Levels},
  journal = {Water},
  year = {2026},
  volume = {18},
  number = {14},
  pages = {1756},
  doi = {10.3390/w18141756}
}
Kostenlos starten →