EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental and Numerical Study of Flow over the Weir–Flume Combination Facility

Fan Yang, Gang Ling, Jichao Yang, Hui Wang, Yuxiang Ba, Xingjiao Yu, Wene Wang, Xiaotao Hu

Water · 19.07.2026 · 18 (14) · 1747

DOI: 10.3390/w18141747 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water, online erschienen am 19.07.2026. Verfasst von Fan Yang und 7 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National key research and development program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The weir–flume combination facility is a type of river flow-measurement structure consisting of a flow weir and a Crump weir, designed to integrate flow measurement and upstream backwater regulation, while incorporating a central flume intended to provide a potential passage for aquatic organisms. This study proposes a novel combined weir–flume structure and systematically validates its hydraulic performance through integrated physical experimentation and high-fidelity numerical simulation. Laboratory tests across a flow range of 5–79 L/s revealed longitudinal water surface profiles and Froude number (Fr) distributions. The study findings show that: (1) As the flow increases, the flow regime of the combination facility transitions from flume flow to weir flow, with the critical transition point at a relative water depth of 0.885. (2) The RNG k-ε turbulence model in Flow-3D software (v11.2, Flow Science, Inc., Santa Fe, NM, USA) effectively simulates the flow movement in the weir–flume combination facility, with water depth simulation results closely matching the measured values, and the maximum relative error not exceeding 5%. (3) The Fr and flow velocity in the weir–flume combination facility first increase and then decrease along the length, forming a large, thin water layer area downstream of the facility, where both Fr and flow velocity reach their maximum values. (4) Flow measurement formulas for flume flow and weir flow are obtained through data fitting, with relative errors between the calculated values and measured flow rates being less than 3%. The present study focuses on the hydraulic performance and flow measurement capability of the proposed facility. Although the structural configuration is intended to facilitate ecological passage, its ecological effectiveness was not evaluated and requires further investigation in future studies.

Förderung

  • National Natural Science Foundation of China
  • National key research and development program

Zitieren

APA

Yang, F., Ling, G., Yang, J., Wang, H., Ba, Y., Yu, X., Wang, W., & Hu, X. (2026). Experimental and Numerical Study of Flow over the Weir–Flume Combination Facility. Water, 18(14), 1747. https://doi.org/10.3390/w18141747

Vancouver

Yang F, Ling G, Yang J, Wang H, Ba Y, Yu X, et al. Experimental and Numerical Study of Flow over the Weir–Flume Combination Facility. Water. 2026;18(14):1747. doi:10.3390/w18141747

BibTeX
@article{Yang2026,
  author = {Yang, Fan and Ling, Gang and Yang, Jichao and Wang, Hui and Ba, Yuxiang and Yu, Xingjiao and Wang, Wene and Hu, Xiaotao},
  title = {Experimental and Numerical Study of Flow over the Weir–Flume Combination Facility},
  journal = {Water},
  year = {2026},
  volume = {18},
  number = {14},
  pages = {1747},
  doi = {10.3390/w18141747}
}
Kostenlos starten →