EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of Integrated Biofilm-Phytoremediation Process in Reclaiming Water from Domestic Wastewater

Fairuz Afiqah Buslima, Hassimi Abu Hasan, Jahira Alias, Jaga Sahsiny Jaganathan, Junaidah Buhari, Suriya Vathi Subramanian, Siti Rozaimah Sheikh Abdullah

Water · 09.01.2025 · 17 (2) · 163

DOI: 10.3390/w17020163 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water, online erschienen am 09.01.2025. Verfasst von Fairuz Afiqah Buslima und 6 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Higher Education, Malaysia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid development of the residential and industrial sectors produces a huge amount of treated domestic wastewater. The treated wastewater is discharged and could affect the environment in the long term. Improving the quality of treated domestic wastewater for water reclamation would benefit both sectors. This study aims to determine the efficiency of the biofilm-phytoremediation integration process in reclaiming domestic wastewater. A cuboid-shaped reactor was filled with 15 L of domestic wastewater, utilizing water hyacinth and a polyethylene carrier as supporting media for the process. The integrated reactor is tested in two phases: the initial adaptation of bacteria with domestic and synthetic wastewater (Phase I) and the integration process of biofilm-phytoremediation, based on the factors of NH3-N concentration and hydraulic retention time (HRT), for 24 to 48 h (Phase II). In Phase II, pollutant removal was observed at varying NH3-N concentrations: C1 (11–13 mg/L), C2 (9–11 mg/L), and C3 (3–5 mg/L). The study’s findings indicate a consistent performance in the first phase, with removal rates for COD and NH3-N ranging between 86.7–100.0% and 79.0–99.6%, respectively. The reactor effectively removed pollutants at varying concentrations of NH3-N, with average removal up to 100% (COD), 99% (NH3-N), and 80% (PO43−). This integrated reactor shows the finest treated water quality outcomes for non-potable water recovery, as well as offers an alternative to resolve water scarcity for use in various sectors.

Förderung

  • Ministry of Higher Education, Malaysia

Zitieren

APA

Buslima, F. A., Hasan, H. A., Alias, J., Jaganathan, J. S., Buhari, J., Subramanian, S. V., & Abdullah, S. R. S. (2025). Performance of Integrated Biofilm-Phytoremediation Process in Reclaiming Water from Domestic Wastewater. Water, 17(2), 163. https://doi.org/10.3390/w17020163

Vancouver

Buslima FA, Hasan HA, Alias J, Jaganathan JS, Buhari J, Subramanian SV, et al. Performance of Integrated Biofilm-Phytoremediation Process in Reclaiming Water from Domestic Wastewater. Water. 2025;17(2):163. doi:10.3390/w17020163

BibTeX
@article{Buslima2025,
  author = {Buslima, Fairuz Afiqah and Hasan, Hassimi Abu and Alias, Jahira and Jaganathan, Jaga Sahsiny and Buhari, Junaidah and Subramanian, Suriya Vathi and Abdullah, Siti Rozaimah Sheikh},
  title = {Performance of Integrated Biofilm-Phytoremediation Process in Reclaiming Water from Domestic Wastewater},
  journal = {Water},
  year = {2025},
  volume = {17},
  number = {2},
  pages = {163},
  doi = {10.3390/w17020163}
}
Kostenlos starten →