Long-Term Stability of Low-Cost IoT System for Monitoring Water Quality in Urban Rivers
Water · 15.06.2024 · 16 (12) · 1708
DOI: 10.3390/w16121708 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water, online erschienen am 15.06.2024. Verfasst von Manel Naloufi und 11 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: long-term research programs Forbath and OPUR (Observatoire des Polluants Urbains), University of Paris-Est Créteil, City of Paris and the French Association Nationale de la Recherche et de la Technologie.
Abstract (Originalsprache)
Monitoring water quality in urban rivers is crucial for water resource management since point and non-point source pollution remain a major challenge. However, traditional water quality monitoring methods are costly and limited in frequency and spatial coverage. To optimize the monitoring, techniques such as modeling have been proposed. These methods rely on networks of low-cost multiprobes integrated with IoT networks to offer continuous real-time monitoring, with sufficient spatial coverage. But challenges persist in terms of data quality. Here, we propose a framework to verify the reliability and stability of low-cost sensors, focusing on the implementation of multiparameter probes embedding six sensors. Various tests have been developed to validate these sensors. First of all, a calibration check was carried out, indicating good accuracy. We then analyzed the influence of temperature. This revealed that for the conductivity and the oxygen sensors, a temperature compensation was required, and correction coefficients were identified. Temporal stability was verified in the laboratory and in the field (from 3 h to 3 months), which helped identify the frequency of maintenance procedures. To compensate for the sensor drift, weekly calibration and cleaning were required. This paper also explores the feasibility of LoRa technology for real-time data retrieval. However, with the LoRa gateways tested, the communication distance with the sensing device did not exceed 200 m. Based on these results, we propose a validation method to verify and to assure the performance of the low-cost sensors for water quality monitoring.
Förderung
- long-term research programs Forbath and OPUR (Observatoire des Polluants Urbains)
- University of Paris-Est Créteil
- City of Paris and the French Association Nationale de la Recherche et de la Technologie
Zitieren
APA
Naloufi, M., Abreu, T., Souihi, S., Therial, C., Rodrigues, N. A. D. P., Goff, A. G. L., Saad, M., Vinçon-Leite, B., Dubois, P., Delarbre, M., Kennouche, P., & Lucas, F. S. (2024). Long-Term Stability of Low-Cost IoT System for Monitoring Water Quality in Urban Rivers. Water, 16(12), 1708. https://doi.org/10.3390/w16121708
Vancouver
Naloufi M, Abreu T, Souihi S, Therial C, Rodrigues NADP, Goff AGL, et al. Long-Term Stability of Low-Cost IoT System for Monitoring Water Quality in Urban Rivers. Water. 2024;16(12):1708. doi:10.3390/w16121708
BibTeX
@article{Naloufi2024,
author = {Naloufi, Manel and Abreu, Thiago and Souihi, Sami and Therial, Claire and Rodrigues, Natália Angelotti de Ponte and Goff, Arthur Guillot Le and Saad, Mohamed and Vinçon-Leite, Brigitte and Dubois, Philippe and Delarbre, Marion and Kennouche, Paul and Lucas, Françoise S.},
title = {Long-Term Stability of Low-Cost IoT System for Monitoring Water Quality in Urban Rivers},
journal = {Water},
year = {2024},
volume = {16},
number = {12},
pages = {1708},
doi = {10.3390/w16121708}
}
EUVIMED