EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Intelligent Chemical Dosing System for Phosphorus Removal in Wastewater Treatment Plants

Xi Lu, Song Huang, Haichen Liu, Fengwei Yang, Ting Zhang, Xinyu Wan

Water · 06.06.2024 · 16 (11) · 1623

DOI: 10.3390/w16111623 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water, online erschienen am 06.06.2024. Verfasst von Xi Lu und 5 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Research Project of Shanghai Investigation, Design & Research Institute Co., Ltd., Shanghai Action Plan for Science, Technology and Innovation, Research Project of YANGTZE Eco-Environment Engineering Research Center, China Three Gorges Corporation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Whether the phosphorus removal chemical in wastewater treatment plants (WWTPs) can be accurately dosed not only affects the compliance of the effluent total phosphorus but also has a huge impact on sludge production and energy consumption during the wastewater treatment process. For the effluent from the secondary sedimentation tank of a wastewater treatment plant in southern China, based on experimental screening of the optimal pH value, chemical types and concentrations of chemicals, coagulation time, etc., a dynamic dosage prediction feedforward model for chemical phosphorus removal agents in the effluent from the secondary sedimentation tank of the WWTPs was developed to predict the most economical dosage of the chemicals. Meanwhile, combined with the adaptive fuzzy neural network P feedback control algorithm, dynamic real-time control of chemical dosing was achieved. Through micro-control design, a software model for signal collection and feedback in a specific phosphorus removal scenario was formed, and an automatic control system for chemical dosing was ultimately developed for a WWTP in a city in southern China. After stable operation for two months, the system achieved a 100% compliance rate for effluent total phosphorus (TP) concentration and a 67% improvement in effluent stability, helping the wastewater treatment plant achieve stable and precise control of the phosphorus removal process in the secondary sedimentation tank effluent, which is conducive to further promoting its implementation of low-carbon pathways.

Förderung

  • the Research Project of Shanghai Investigation, Design & Research Institute Co., Ltd.
  • Shanghai Action Plan for Science, Technology and Innovation
  • Research Project of YANGTZE Eco-Environment Engineering Research Center, China Three Gorges Corporation

Zitieren

APA

Lu, X., Huang, S., Liu, H., Yang, F., Zhang, T., & Wan, X. (2024). Research on Intelligent Chemical Dosing System for Phosphorus Removal in Wastewater Treatment Plants. Water, 16(11), 1623. https://doi.org/10.3390/w16111623

Vancouver

Lu X, Huang S, Liu H, Yang F, Zhang T, Wan X. Research on Intelligent Chemical Dosing System for Phosphorus Removal in Wastewater Treatment Plants. Water. 2024;16(11):1623. doi:10.3390/w16111623

BibTeX
@article{Lu2024,
  author = {Lu, Xi and Huang, Song and Liu, Haichen and Yang, Fengwei and Zhang, Ting and Wan, Xinyu},
  title = {Research on Intelligent Chemical Dosing System for Phosphorus Removal in Wastewater Treatment Plants},
  journal = {Water},
  year = {2024},
  volume = {16},
  number = {11},
  pages = {1623},
  doi = {10.3390/w16111623}
}
Kostenlos starten →