Structure Integrity Analysis Using Fluid–Structure Interaction at Hydropower Bottom Outlet Discharge
Water · 09.03.2023 · 15 (6) · 1039
DOI: 10.3390/w15061039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water, online erschienen am 09.03.2023. Verfasst von Mohd Rashid Mohd Radzi und 8 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UNITEN R&D Sdn. Bhd.
Abstract (Originalsprache)
Dam reliability analysis is performed to determine the structural integrity of dams and, hence, to prevent dam failure. The Chenderoh Dam structure is divided into five parts: the left bank, right bank, spillway, intake section, and bottom outlet, with each element performing standalone functions to maintain the overall Dam’s continuous operation. This study presents a numerical reliability analysis of water dam reservoir banks using fluid–structure interaction (FSI) simulation of the bottom outlet structures operated at different discharge conditions. Three-dimensional computer-aided drawings were used to view the overall Chenderoh Dam. Next, a two-way fluid–structure interaction (FSI) model was developed to explore the influence of fluid flow and structural deformation on dam systems. The FSI modeling consists of Ansys Fluent and Ansys Structural modules to consider the boundary conditions separately. The reliability and performance of the reservoir bottom outlet structure was effectively simulated and recognised using FSI. The maximum stress on the bottom outlet section is 18.4 MPa, which is lower than the yield stress of mild steel of 370 MPa. Therefore, there will be no structural failure being observed on the bottom outlet section when the butterfly valve is fully closed. With a few exceptions, the FSI models projected that bottom outlet structures would be able to run under specified conditions without structural collapse or requiring interventions due to having lower stress than the material’s yield strength.
Förderung
- UNITEN R&D Sdn. Bhd
Zitieren
APA
Radzi, M. R. M., Zawawi, M. H., Abas, M. A., Mazlan, A. Z. A., Zainol, M. R. R. M. A., Hassan, N. H., Zanial, W. N. C. W., Dullah, H., & Kamaruddin, M. A. (2023). Structure Integrity Analysis Using Fluid–Structure Interaction at Hydropower Bottom Outlet Discharge. Water, 15(6), 1039. https://doi.org/10.3390/w15061039
Vancouver
Radzi MRM, Zawawi MH, Abas MA, Mazlan AZA, Zainol MRRMA, Hassan NH, et al. Structure Integrity Analysis Using Fluid–Structure Interaction at Hydropower Bottom Outlet Discharge. Water. 2023;15(6):1039. doi:10.3390/w15061039
BibTeX
@article{Radzi2023,
author = {Radzi, Mohd Rashid Mohd and Zawawi, Mohd Hafiz and Abas, Mohamad Aizat and Mazlan, Ahmad Zhafran Ahmad and Zainol, Mohd Remy Rozainy Mohd Arif and Hassan, Nurul Husna and Zanial, Wan Norsyuhada Che Wan and Dullah, Hayana and Kamaruddin, Mohamad Anuar},
title = {Structure Integrity Analysis Using Fluid–Structure Interaction at Hydropower Bottom Outlet Discharge},
journal = {Water},
year = {2023},
volume = {15},
number = {6},
pages = {1039},
doi = {10.3390/w15061039}
}
EUVIMED