EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

When Cronbach’s Alpha Is Not Enough: Implications for the Clinical Use of Vision-Related Patient-Reported Outcomes

Mario Cantó-Cerdán iD, María C Martínez-Hergueta iD, Ana Siverio-Colomina, Pilar Yébana-Rubio, Jorge Alió-Del-Barrio iD, Pilar Cacho-Martínez iD, Ángel García-Muñoz iD, Antonio Martínez-Abad iD

Vision · 06.08.2026 · 10 (3) · 52

DOI: 10.3390/vision10030052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vision, online erschienen am 06.08.2026. Verfasst von Mario Cantó-Cerdán und 7 weiteren Autor:innen. Beteiligte Einrichtung: Vissum (Miranza Group), 03016 Alicante, Spain. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Patient-reported outcome measures (PROMs) in vision science are commonly evaluated using Cronbach’s alpha, yet Rasch-based statistics may provide different information about their reliability. This study compared Cronbach’s alpha, a Classical Test Theory (CTT) index, with Rasch person reliability and the person separation ratio across three vision-related questionnaires: the Symptom Questionnaire for Visual Dysfunctions (SQVD; n = 434), the Ocular Surface Disease Index (OSDI; n = 294), and the Quality of Vision questionnaire (QoV; n = 288), using retrospective data from unselected clinical populations. Cronbach’s alpha indicated acceptable internal consistency across all questionnaires (α = 0.80–0.87), whereas Rasch person reliability was lower (0.62–0.80) and person separation ratios ranged from 1.29 to 2.00, indicating more limited discrimination. Item reliability was generally high (0.90–0.97) overall but declined in subgroups with restricted score variability. Discrepancies were most pronounced in the OSDI, where estimates approached their theoretical floor when subgroups were defined by the questionnaire’s own scores. Cronbach’s alpha and Rasch-based statistics are not interchangeable and capture different aspects of measurement precision: alpha may overestimate internal consistency, whereas person reliability and the separation ratio provide complementary information about discriminatory capacity. These findings support reporting both CTT and Rasch-based reliability statistics when evaluating vision-related PROMs in clinical populations.

Schlagwörter

Stichwörter der Autor:innen

Cronbach’s alphaRasch analysisclassical test theorymeasurement reliabilitypatient-reported outcomesperson separation ratiovision

Autor:innen und Institutionen

  • Vissum (Miranza Group), 03016 Alicante, Spain.
  • Grupo de Investigación en Optometría (GIOptom), University of Alicante, 03690 Alicante, Spain.
  • Ophthalmology Department, Hospital General de Elda, 03600 Alicante, Spain.
  • Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, 03550 Alicante, Spain.

ORCID-Profile: Mario Cantó-Cerdán, María C Martínez-Hergueta, Jorge Alió-Del-Barrio, Pilar Cacho-Martínez, Ángel García-Muñoz, Antonio Martínez-Abad

Zitieren

APA

Cantó-Cerdán, M., Martínez-Hergueta, M. C., Siverio-Colomina, A., Yébana-Rubio, P., Alió-Del-Barrio, J., Cacho-Martínez, P., García-Muñoz, Á., & Martínez-Abad, A. (2026). When Cronbach’s Alpha Is Not Enough: Implications for the Clinical Use of Vision-Related Patient-Reported Outcomes. Vision, 10(3), 52. https://doi.org/10.3390/vision10030052

Vancouver

Cantó-Cerdán M, Martínez-Hergueta MC, Siverio-Colomina A, Yébana-Rubio P, Alió-Del-Barrio J, Cacho-Martínez P, et al. When Cronbach’s Alpha Is Not Enough: Implications for the Clinical Use of Vision-Related Patient-Reported Outcomes. Vision. 2026;10(3):52. doi:10.3390/vision10030052

BibTeX
@article{CantCerdn2026,
  author = {Cantó-Cerdán, Mario and Martínez-Hergueta, María C and Siverio-Colomina, Ana and Yébana-Rubio, Pilar and Alió-Del-Barrio, Jorge and Cacho-Martínez, Pilar and García-Muñoz, Ángel and Martínez-Abad, Antonio},
  title = {When Cronbach’s Alpha Is Not Enough: Implications for the Clinical Use of Vision-Related Patient-Reported Outcomes},
  journal = {Vision},
  year = {2026},
  volume = {10},
  number = {3},
  pages = {52},
  doi = {10.3390/vision10030052}
}
Kostenlos starten →