EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reference Intervals for Serum Protein Electrophoresis in the European Bison (Bison bonasus): A Comparison of Agarose Gel Electrophoresis and Capillary Zone Electrophoresis

Anna Didkowska iD, Victor Martín Santander, Daniel Klich iD, Michal Skibniewski iD, Katarzyna Matusik, Marlena Wojciechowska iD, Wanda Olech iD, Krysztof Anusz iD, Diana Marteles-Aragüés, Sergio Villanueva-Saz iD, Antonio Fernández iD

Veterinary Sciences · 30.06.2026 · 13 (7) · 644

DOI: 10.3390/vetsci13070644 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Sciences, online erschienen am 30.06.2026. Verfasst von Anna Didkowska und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Food Hygiene and Public Health Protection, Institute of Veterinary Medicine, Warsaw University of Life Sciences (SGGW), Nowoursynowska …. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Forest Fund, Aragon Government, European Social Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Knowledge of the reference intervals for serum proteins of the European bison (Bison bonasus) can be of great help in the diagnosis of infectious and inflammatory diseases, which are very common in these animals; however, reference intervals for this species are unknown. A total of 131 serum samples were obtained from the European bison from different locations in Poland. Agarose gel electrophoresis (AGE) and capillary zone electrophoresis (CZE) were used to separate and identify protein fractions. In all sera, six fractions were identified: albumin, α1, α2, β1-, β2-, and γ-globulins by both analytical methods. Reference intervals (90% CI) were determined. Comparisons were made to find significant differences based on the sex, age or lifestyle of the animals. Concordance between the methods was assessed using Passing–Bablok regression, Bland–Altman analysis, and Lin’s concordance correlation. A higher percentage of α1-globulins was found in the females than in the males. Captive bison had significantly lower γ-globulin levels compared to free-living bison. The γ-globulin levels increased with the age of the animals. The Bland–Altman analysis demonstrated a systematic bias indicating no good agreement between methods, and only the values for albumin, β1-, β2-, γ-globulins, and total globulins were considered acceptable according to Lin’s concordance correlation. Both methods are adequate for identifying serum proteins, but they are not interchangeable, necessitating the use of separate reference intervals for each method.

Schlagwörter

Stichwörter der Autor:innen

AGECZEEuropean bisonreference intervalsserum proteins

Autor:innen und Institutionen

  • Department of Food Hygiene and Public Health Protection, Institute of Veterinary Medicine, Warsaw University of Life Sciences (SGGW), Nowoursynowska 166, 02-787 Warsaw, Poland.
  • Department of Animal Pathology, Instituto Agroalimentario de Aragón-IA2 (Universidad de Zaragoza-CITA), Veterinary Faculty, University of Zaragoza, 50013 Zaragoza, Spain.
  • Clinical Immunology Laboratory, Veterinary Faculty, University of Zaragoza, 50013 Zaragoza, Spain.
  • Department of Animal Genetics and Conservation, Warsaw University of Life Sciences (SGGW), Ciszewskiego 8, 02-786 Warsaw, Poland.
  • Department of Morphological Sciences, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, 02-776 Warsaw, Poland.

ORCID-Profile: Anna Didkowska, Daniel Klich, Michal Skibniewski, Marlena Wojciechowska, Wanda Olech, Krysztof Anusz, Sergio Villanueva-Saz, Antonio Fernández

Förderung

  • Forest Fund
  • Aragon Government
  • European Social Fund
  • Cátedra UNIZAR-UNITED PET FOOD

Zitieren

APA

Didkowska, A., Martín Santander, V., Klich, D., Skibniewski, M., Matusik, K., Wojciechowska, M., Olech, W., Anusz, K., Marteles-Aragüés, D., Villanueva-Saz, S., & Fernández, A. (2026). Reference Intervals for Serum Protein Electrophoresis in the European Bison (Bison bonasus): A Comparison of Agarose Gel Electrophoresis and Capillary Zone Electrophoresis. Veterinary Sciences, 13(7), 644. https://doi.org/10.3390/vetsci13070644

Vancouver

Didkowska A, Martín Santander V, Klich D, Skibniewski M, Matusik K, Wojciechowska M, et al. Reference Intervals for Serum Protein Electrophoresis in the European Bison (Bison bonasus): A Comparison of Agarose Gel Electrophoresis and Capillary Zone Electrophoresis. Veterinary Sciences. 2026;13(7):644. doi:10.3390/vetsci13070644

BibTeX
@article{Didkowska2026,
  author = {Didkowska, Anna and Martín Santander, Victor and Klich, Daniel and Skibniewski, Michal and Matusik, Katarzyna and Wojciechowska, Marlena and Olech, Wanda and Anusz, Krysztof and Marteles-Aragüés, Diana and Villanueva-Saz, Sergio and Fernández, Antonio},
  title = {Reference Intervals for Serum Protein Electrophoresis in the European Bison (Bison bonasus): A Comparison of Agarose Gel Electrophoresis and Capillary Zone Electrophoresis},
  journal = {Veterinary Sciences},
  year = {2026},
  volume = {13},
  number = {7},
  pages = {644},
  doi = {10.3390/vetsci13070644}
}
Kostenlos starten →