Fachartikel in der Zeitschrift Toxins, 2025. Verfasst von Naga Adithya Chandra Pandurangi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Universitat Rovira i Virgili, 43007 Tarragona, Spain. Hauptthemen laut MEDLINE: Tetrodotoxin, Tin Compounds, Electrochemical Techniques. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Marie Skłodowska-Curie.
Abstract (Originalsprache)
The real-time, cost-effective detection of marine toxins like tetrodotoxin (TTX) remains a significant challenge for the scientific community. Traditional methods, including cell-based assays (CBAs), high-performance liquid chromatography (HPLC), and automated patch clamp (APC), are time-consuming, requiring expensive lab-based equipment and highly trained personnel. Enzyme-linked immunosorbent assays (ELISAs), lateral flow assays (LFAs), and immunosensors may not be suitable for toxin analogues. Thus, a simplified approach has been developed in this study, which involves the electrophysiological and electrochemical interrogation of N2a cells grown on ITO-coated glass electrodes by measuring extracellular field potentials (EFP) in conjunction with whole-cell patch clamp recordings and electrochemical impedance spectroscopy (EIS) measurements both before and after incubation with TTX. The ITO substrate proved biocompatible and non-toxic for N2a cells. TTX exposure caused 102% inhibition in EFP values at 300 nM, confirmed by sodium current inhibition of 93% at 300 nM and 22% at 1 nM in patch clamp studies (IC50 = 6.7 nM). EIS measurements indicated concentration-dependent impedance changes in the range of 6–300 nM. This research aims to provide a proof-of-concept for integration of electrophysiological and electrochemical approaches to simplify toxin detection systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Universitat Rovira i Virgili, 43007 Tarragona, Spain.
- Department of Basic Medical Sciences, Universitat Rovira i Virgili, C/Sant Llorenç 21, 43201 Reus, Spain.
- Reading School of Pharmacy, University of Reading, Reading RG6 6UR, UK.
ORCID-Profile: Naga Adithya Chandra Pandurangi, Manel M Santafe, Nagihan Ozsoy, Fransesc X Sureda, Mark L Dallas, Ioanis Katakis
Förderung
- Marie Skłodowska-Curie
Zitieren
APA
Pandurangi, N. A. C., Santafe, M. M., Tudo, A., Ozsoy, N., Sureda, F. X., Dallas, M. L., & Katakis, I. (2025). Cost-Effective and Rapid Detection of Tetrodotoxin Using Indium Tin Oxide Electrodes via In Vitro Electrophysiology and Electrochemistry. Toxins. https://doi.org/10.3390/toxins17090462
Vancouver
Pandurangi NAC, Santafe MM, Tudo A, Ozsoy N, Sureda FX, Dallas ML, et al. Cost-Effective and Rapid Detection of Tetrodotoxin Using Indium Tin Oxide Electrodes via In Vitro Electrophysiology and Electrochemistry. Toxins. 2025. doi:10.3390/toxins17090462
BibTeX
@article{Pandurangi2025,
author = {Pandurangi, Naga Adithya Chandra and Santafe, Manel M and Tudo, Angels and Ozsoy, Nagihan and Sureda, Fransesc X and Dallas, Mark L and Katakis, Ioanis},
title = {Cost-Effective and Rapid Detection of Tetrodotoxin Using Indium Tin Oxide Electrodes via In Vitro Electrophysiology and Electrochemistry},
journal = {Toxins},
year = {2025},
doi = {10.3390/toxins17090462}
}
EUVIMED