Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces
Toxics · 02.08.2024 · 12 (8) · 563
DOI: 10.3390/toxics12080563 ↗Kurz gefasst
Fachartikel in der Zeitschrift Toxics, online erschienen am 02.08.2024. Verfasst von Zhaohua Sun und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Transportation and Civil Engineering, Nantong University, Nantong 226019, China. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Laboratory of New Technology for Construction of Cities in Mountain Area.
Abstract (Originalsprache)
Electrokinetic remediation (EKR) has shown great potential for the remediation of in situ contaminated soils. For heavy metal-contaminated soft clay with high moisture content and low permeability, an electrokinetic remediation method with electrolytes placed above the ground surface is used to avoid issues such as electrolyte leakage and secondary contamination that may arise from directly injecting electrolytes into the soil. In this context, using this novel experimental device, a set of citric acid (CA)-enhanced EKR tests were conducted to investigate the optimal design parameters for Cu- and Zn-contaminated soft clay. The average removal rates of heavy metals Cu and Zn in these tests were in the range of 27.9–85.5% and 63.9–83.5%, respectively. The results indicate that the Zn removal was efficient. This was determined by the migration intensity of the electro-osmotic flow, particularly the volume reduction of the anolyte. The main factors affecting the Cu removal efficiency in sequence were the effective electric potential of the contaminated soft clay and the electrolyte concentration. Designing experimental parameters based on these parameters will help remove Cu and Zn. Moreover, the shear strength of the contaminated soil was improved; however, the degree of improvement was limited. Low-concentration CA can effectively control the contact resistance between the anode and soil, the contact resistance between the cathode and soil, and the soil resistance by increasing the amount of electrolyte and the contact area between the electrolyte and soil.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Transportation and Civil Engineering, Nantong University, Nantong 226019, China.
- Key Laboratory of New Technology for Construction of Cities in Mountain Area, Ministry of Education, Chongqing University, Chongqing 400045, China.
ORCID-Profile: Zhaohua Sun
Förderung
- National Natural Science Foundation of China
- Key Laboratory of New Technology for Construction of Cities in Mountain Area
Zitieren
APA
Sun, Z., Geng, J., Zhang, C., & Du, Q. (2024). Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces. Toxics, 12(8), 563. https://doi.org/10.3390/toxics12080563
Vancouver
Sun Z, Geng J, Zhang C, Du Q. Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces. Toxics. 2024;12(8):563. doi:10.3390/toxics12080563
BibTeX
@article{Sun2024,
author = {Sun, Zhaohua and Geng, Jingxian and Zhang, Cheng and Du, Qiu},
title = {Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces},
journal = {Toxics},
year = {2024},
volume = {12},
number = {8},
pages = {563},
doi = {10.3390/toxics12080563}
}
EUVIMED