EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces

Zhaohua Sun iD, Jingxian Geng, Cheng Zhang, Qiu Du

Toxics · 02.08.2024 · 12 (8) · 563

DOI: 10.3390/toxics12080563 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Toxics, online erschienen am 02.08.2024. Verfasst von Zhaohua Sun und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Transportation and Civil Engineering, Nantong University, Nantong 226019, China. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Laboratory of New Technology for Construction of Cities in Mountain Area.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrokinetic remediation (EKR) has shown great potential for the remediation of in situ contaminated soils. For heavy metal-contaminated soft clay with high moisture content and low permeability, an electrokinetic remediation method with electrolytes placed above the ground surface is used to avoid issues such as electrolyte leakage and secondary contamination that may arise from directly injecting electrolytes into the soil. In this context, using this novel experimental device, a set of citric acid (CA)-enhanced EKR tests were conducted to investigate the optimal design parameters for Cu- and Zn-contaminated soft clay. The average removal rates of heavy metals Cu and Zn in these tests were in the range of 27.9–85.5% and 63.9–83.5%, respectively. The results indicate that the Zn removal was efficient. This was determined by the migration intensity of the electro-osmotic flow, particularly the volume reduction of the anolyte. The main factors affecting the Cu removal efficiency in sequence were the effective electric potential of the contaminated soft clay and the electrolyte concentration. Designing experimental parameters based on these parameters will help remove Cu and Zn. Moreover, the shear strength of the contaminated soil was improved; however, the degree of improvement was limited. Low-concentration CA can effectively control the contact resistance between the anode and soil, the contact resistance between the cathode and soil, and the soil resistance by increasing the amount of electrolyte and the contact area between the electrolyte and soil.

Schlagwörter

Stichwörter der Autor:innen

citric acidelectrokinetic remediationelectrolyteheavy metalremoval efficiencysoft clay

Autor:innen und Institutionen

  • School of Transportation and Civil Engineering, Nantong University, Nantong 226019, China.
  • Key Laboratory of New Technology for Construction of Cities in Mountain Area, Ministry of Education, Chongqing University, Chongqing 400045, China.

ORCID-Profile: Zhaohua Sun

Förderung

  • National Natural Science Foundation of China
  • Key Laboratory of New Technology for Construction of Cities in Mountain Area

Zitieren

APA

Sun, Z., Geng, J., Zhang, C., & Du, Q. (2024). Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces. Toxics, 12(8), 563. https://doi.org/10.3390/toxics12080563

Vancouver

Sun Z, Geng J, Zhang C, Du Q. Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces. Toxics. 2024;12(8):563. doi:10.3390/toxics12080563

BibTeX
@article{Sun2024,
  author = {Sun, Zhaohua and Geng, Jingxian and Zhang, Cheng and Du, Qiu},
  title = {Electrokinetic Remediation of Cu- and Zn-Contaminated Soft Clay with Electrolytes Situated above Soil Surfaces},
  journal = {Toxics},
  year = {2024},
  volume = {12},
  number = {8},
  pages = {563},
  doi = {10.3390/toxics12080563}
}
Kostenlos starten →