EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Variant Sciatic Nerve Anatomy in Relation to the Piriformis Muscle on Magnetic Resonance Neurography: A Potential Etiology for Extraspinal Sciatica

Upasana Upadhyay Bharadwaj iD, Vanja Varenika, William Carson, Javier Villanueva-Meyer, Simon Ammanuel, Matthew Bucknor, Nathaniel M Robbins iD, Vanja Douglas, Cynthia T Chin

Tomography · 22.02.2023 · 9 (2) · 475-484

DOI: 10.3390/tomography9020039 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, online erschienen am 22.02.2023. Verfasst von Upasana Upadhyay Bharadwaj und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA. Hauptthemen laut MEDLINE: Sciatica. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the prevalence and clinical implications of variant sciatic nerve anatomy in relation to the piriformis muscle on magnetic resonance neurography (MRN), in patients with lumbosacral neuropathic symptoms. Materials and Methods: In this retrospective single-center study, 254 sciatic nerves, from 127 patients with clinical and imaging findings compatible with extra-spinal sciatica on MRN between 2003 and 2013, were evaluated for the presence and type of variant sciatic nerves, split sciatic nerve, abnormal T2-signal hyperintensity, asymmetric piriformis size and increased nerve caliber, and summarized using descriptive statistics. Two-tailed chi-square tests were performed to compare the anatomical variant type and clinical symptoms between imaging and clinical characteristics.

Results

Sixty-four variant sciatic nerves were identified with an equal number of right and left variants. Bilateral variants were noted in 15 cases. Abnormal T2-signal hyperintensity was seen significantly more often in variant compared to conventional anatomy (40/64 vs. 82/190; p = 0.01). A sciatic nerve split was seen significantly more often in variant compared to conventional anatomy (56/64 vs. 20/190; p < 0.0001). Increased nerve caliber, abnormal T2-signal hyperintensity, and asymmetric piriformis size were significantly associated with the clinically symptomatic side compared to the asymptomatic side (98:2, 98:2, and 97:3, respectively; p < 0.0001 for all). Clinical symptoms were correlated with variant compared to conventional sciatic nerve anatomy (64% vs. 46%; p = 0.01).

Conclusion

Variant sciatic nerve anatomy, in relation to the piriformis muscle, is frequently identified with MRN and is more likely to be associated with nerve signal changes and symptomatology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SciaticaHumansRetrospective StudiesMagnetic Resonance ImagingSciatic NerveMuscle, SkeletalMagnetic Resonance Spectroscopy

Stichwörter der Autor:innen

MRIneurogrampiriformissciatic nervevariant anatomy

Autor:innen und Institutionen

  • Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA.
  • RadNet Northern California, RadNet Imaging Centers, San Francisco, CA 90815, USA.
  • Southwest Medical Imaging, Scottsdale, AZ 85258, USA.
  • Department of Neurological Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI 53705, USA.
  • Department of Neurology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA.
  • Department of Neurology, UCSF Weill Institute for Neurosciences, San Francisco, CA 94143, USA.

ORCID-Profile: Upasana Upadhyay Bharadwaj, Nathaniel M Robbins

Zitieren

APA

Bharadwaj, U. U., Varenika, V., Carson, W., Villanueva-Meyer, J., Ammanuel, S., Bucknor, M., Robbins, N. M., Douglas, V., & Chin, C. T. (2023). Variant Sciatic Nerve Anatomy in Relation to the Piriformis Muscle on Magnetic Resonance Neurography: A Potential Etiology for Extraspinal Sciatica. Tomography, 9(2), 475-484. https://doi.org/10.3390/tomography9020039

Vancouver

Bharadwaj UU, Varenika V, Carson W, Villanueva-Meyer J, Ammanuel S, Bucknor M, et al. Variant Sciatic Nerve Anatomy in Relation to the Piriformis Muscle on Magnetic Resonance Neurography: A Potential Etiology for Extraspinal Sciatica. Tomography. 2023;9(2):475-484. doi:10.3390/tomography9020039

BibTeX
@article{Bharadwaj2023,
  author = {Bharadwaj, Upasana Upadhyay and Varenika, Vanja and Carson, William and Villanueva-Meyer, Javier and Ammanuel, Simon and Bucknor, Matthew and Robbins, Nathaniel M and Douglas, Vanja and Chin, Cynthia T},
  title = {Variant Sciatic Nerve Anatomy in Relation to the Piriformis Muscle on Magnetic Resonance Neurography: A Potential Etiology for Extraspinal Sciatica},
  journal = {Tomography},
  year = {2023},
  volume = {9},
  number = {2},
  pages = {475--484},
  doi = {10.3390/tomography9020039}
}
Kostenlos starten →