EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications

Francesco Paparo, Nicola Panvini, Enrico Francesco Melani, Marco Magliocco, Giuseppe Cittadini, Lucio Molini, Giovanni Pratesi, Giovanni Spinella

Tomography · 18.11.2026 · 12 (11) · 166

DOI: 10.3390/tomography12110166 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Tomography, online erschienen am 18.11.2026. Verfasst von Francesco Paparo und 7 weiteren Autor:innen. Die Arbeit nennt 135 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Computed tomography (CT) and CT angiography (CTA) are central to assessing aortic aneurysm and dissection, but manual segmentation and geometric analysis remain time-consuming and operator-dependent, while evidence on artificial intelligence (AI) is fragmented. This task-based systematic review synthesised AI applications to CT/CTA of the thoracic and abdominal aorta by primary task: segmentation, measurement, or detection and classification.

Methods

PubMed/MEDLINE and Europe PMC were searched from 2015 to September 2026 following PRISMA 2020; the protocol was registered retrospectively (INPLASY2026110004). Segmentation and measurement studies were appraised with CLAIM and detection studies with QUADAS-2/QUADAS-AI, and results were synthesised without meta-analysis.

Results

Of 118 included studies (42 segmentation, 38 measurement, 38 detection), half were published since 2024. Median Dice similarity coefficient was 0.90 or higher for the outer wall, lumen and true and false lumina, but 0.86 for intraluminal thrombus and 0.63 for false lumen thrombus. Automated maximum diameter showed a median absolute bias of 0.26 mm (95% limits of agreement about ±5 mm). Detection of aortic dissection reached a median AUC of 0.96–0.97, mostly in enriched samples. External validation was reported in 14%, 34% and 55% of segmentation, measurement and detection studies, 33 of 38 detection studies were at high risk of bias, and only two systems were evaluated prospectively.

Conclusions

AI supports technical automation of aortic CT/CTA segmentation and measurement and is progressing toward multistructure geometric phenotyping and clinical decision support, but independent multicentre validation, consecutive cohorts and prospective reader-in-the-loop studies are required before clinical integration. Detection/classification tools require independent diagnostic and workflow validation.

Zitieren

APA

Paparo, F., Panvini, N., Melani, E. F., Magliocco, M., Cittadini, G., Molini, L., Pratesi, G., & Spinella, G. (2026). AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications. Tomography, 12(11), 166. https://doi.org/10.3390/tomography12110166

Vancouver

Paparo F, Panvini N, Melani EF, Magliocco M, Cittadini G, Molini L, et al. AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications. Tomography. 2026;12(11):166. doi:10.3390/tomography12110166

BibTeX
@article{Paparo2026,
  author = {Paparo, Francesco and Panvini, Nicola and Melani, Enrico Francesco and Magliocco, Marco and Cittadini, Giuseppe and Molini, Lucio and Pratesi, Giovanni and Spinella, Giovanni},
  title = {AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications},
  journal = {Tomography},
  year = {2026},
  volume = {12},
  number = {11},
  pages = {166},
  doi = {10.3390/tomography12110166}
}
Kostenlos starten →