Supine CT-Guided Posterior Approach Using a Dorsal-Space Mat: Initial Clinical Experience and Geometric Characterization
Tomography · 2026
DOI: 10.3390/tomography12090134 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, 2026. Verfasst von Yuya Koike und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Nihon University School of Medicine, 30-1, Oyaguchi Kami-cho, Itabashi-ku, Tokyo 173-8610, Japan. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Interventional, Patient Positioning. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Japan Society for the Promotion of Science Grants-in-Aid for Scientific Research.
Abstract (Originalsprache)
Background/Objectives: To evaluate the clinical feasibility, safety, and geometric characteristics of a supine CT-guided posterior approach using a custom dorsal-space mat in patients for whom the supine position was required or preferred.
Methods
This retrospective study included 16 consecutive patients prepared for the approach. Puncture trajectory parameters, positional stability, technical success, procedure time, and adverse events were evaluated in successfully positioned patients (n = 15; 35 trajectories). A geometric model was constructed to estimate maximum allowable puncture angles determined by mat height, needle length, and table geometry.
Results
Positioning feasibility was 15/16 (93.8%); one patient was converted to a lateral approach due to shoulder pain. Technical success was 100% per patient (15/15) and per trajectory (35/35). The mean puncture angle and depth were 40.2° ± 9.1° and 8.3 ± 2.5 cm, respectively. All puncture angles were within theoretical geometric limits, with a mean angular margin of 14.9° ± 10.9°. Quantitative stability assessment was feasible in 14 patients; median two-dimensional displacement and absolute axial rotation were 4.1 mm (IQR, 3.3–4.5 mm) and 0.9° (IQR, 0.3–1.2°), respectively. Between-group differences observed in the trajectory-level analysis were not statistically significant in the patient-level sensitivity analysis. One Grade 5 adverse event occurred after RFA; although a relationship with the procedure could not be excluded, it was unrelated to the mat or puncture trajectory.
Conclusions
This preliminary feasibility study suggests that the dorsal-space mat can provide sufficient working space for CT-guided posterior procedures while maintaining the supine position. Larger prospective studies are required to establish its broader clinical applicability and safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Nihon University School of Medicine, 30-1, Oyaguchi Kami-cho, Itabashi-ku, Tokyo 173-8610, Japan.
- Department of Radiology, Nippon Medical School, 1-1-5, Sendagi, Bunkyo-ku, Tokyo 113-8603, Japan.
ORCID-Profile: Yuya Koike, Tatsuo Ueda
Förderung
- Japan Society for the Promotion of Science
- Japan Society for the Promotion of Science Grants-in-Aid for Scientific Research
Zitieren
APA
Koike, Y., Ueda, T., Sugihara, F., & Tanaka, M. (2026). Supine CT-Guided Posterior Approach Using a Dorsal-Space Mat: Initial Clinical Experience and Geometric Characterization. Tomography. https://doi.org/10.3390/tomography12090134
Vancouver
Koike Y, Ueda T, Sugihara F, Tanaka M. Supine CT-Guided Posterior Approach Using a Dorsal-Space Mat: Initial Clinical Experience and Geometric Characterization. Tomography. 2026. doi:10.3390/tomography12090134
BibTeX
@article{Koike2026,
author = {Koike, Yuya and Ueda, Tatsuo and Sugihara, Fumie and Tanaka, Masashi},
title = {Supine CT-Guided Posterior Approach Using a Dorsal-Space Mat: Initial Clinical Experience and Geometric Characterization},
journal = {Tomography},
year = {2026},
doi = {10.3390/tomography12090134}
}
EUVIMED