A Reproducible Multicentre MRI Radiomics Workflow for Pancreatic Cyst Risk Stratification Using Paired T1- and T2-Weighted Imaging
Tomography · 01.07.2026 · 12 (7) · 100
DOI: 10.3390/tomography12070100 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Tomography, online erschienen am 01.07.2026. Verfasst von George Sgourakis. Beteiligte Einrichtung: HepatoPancreaticBiliary Unit, East Lancashire Hospitals NHS Trust, Blackburn BB2 3HH, UK. Hauptthemen laut MEDLINE: Radiomics, Magnetic Resonance Imaging, Pancreatic Cyst. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To develop and technically validate a reproducible multicentre MRI radiomics workflow for pancreatic cyst risk stratification using paired T1- and T2-weighted imaging from public datasets.
Methods
Public datasets were screened and Cyst-X was selected as the primary cohort because it contained pancreatic MRI, risk labels, masks and metadata. A linked Cyst-X subset was enriched with metadata, filtered to an exact paired T1/T2 cohort, and processed through image–mask quality control, 1.0 mm isotropic resampling, intensity normalisation, PyRadiomics feature extraction, feature reduction and patient-level centre-held-out validation. The revised modelling strategy used a T2 + clinical all-patient primary analysis (n = 409) and a complete-case paired T1/T2 sensitivity analysis (n = 299).
Results
The final cohort comprised 409 patients and 818 image-level rows across EMC, IU, MCF and NYU. All 818 image–mask pairs passed post-preprocessing QC. T2 radiomics were complete for all 409 patients; however, 110 T1 feature sets were missing, all from MCF. In the all-patient T2 + clinical model comparison, logistic regression achieved the highest macro-AUC (0.737). The T2 + clinical random forest comparator achieved macro-AUC 0.716 (95% CI 0.678–0.755), accuracy 0.545 (95% CI 0.496–0.592) and macro-F1 0.530 (95% CI 0.481–0.577). The paired T1/T2 complete-case random forest sensitivity model achieved macro-AUC 0.735 (95% CI 0.691–0.777), accuracy 0.575 (95% CI 0.520–0.632) and macro-F1 0.554 (95% CI 0.494–0.605).
Conclusion
This study demonstrates the feasibility of constructing a reproducible public data MRI radiomics workflow for pancreatic cyst risk stratification. Model performance was modest, and independent external validation is required before clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- HepatoPancreaticBiliary Unit, East Lancashire Hospitals NHS Trust, Blackburn BB2 3HH, UK.
- School of Medicine, University of Lancashire, Preston PR1 2HE, UK.
ORCID-Profile: George Sgourakis
Zitieren
APA
Sgourakis, G. (2026). A Reproducible Multicentre MRI Radiomics Workflow for Pancreatic Cyst Risk Stratification Using Paired T1- and T2-Weighted Imaging. Tomography, 12(7), 100. https://doi.org/10.3390/tomography12070100
Vancouver
Sgourakis G. A Reproducible Multicentre MRI Radiomics Workflow for Pancreatic Cyst Risk Stratification Using Paired T1- and T2-Weighted Imaging. Tomography. 2026;12(7):100. doi:10.3390/tomography12070100
BibTeX
@article{Sgourakis2026,
author = {Sgourakis, George},
title = {A Reproducible Multicentre MRI Radiomics Workflow for Pancreatic Cyst Risk Stratification Using Paired T1- and T2-Weighted Imaging},
journal = {Tomography},
year = {2026},
volume = {12},
number = {7},
pages = {100},
doi = {10.3390/tomography12070100}
}
EUVIMED